This picture assumes the PMA isbeing used as a NETSCOUT InfiniStream Appliance. It shows a minimal set of ports to be connected in order to operate fully.
For other configuration options, please contact COMCERT support.
PMA-222 Min Conn.png
Located on the appliance motherboard:
Management interfaces (MGT) from left to right: 10GBASE-T, 10GBASE-T, 1000BASE-T and 1000BASE-T. One of these ports must be connected to the network. By default, the third port from the left is used as the appliance management interface.
Dedicated virtual console interface (iDRAC). This is a 1000BASE-T Ethernet interface.
Located on the NETSCOUT ASI Accelerator NIC:
Monitor interfaces (MON): 4x SFP+ slots. These slots are empty and are to be equipped with compatible fiber optic transceivers. Attention: copper transceivers are not supported. At least one of these ports must be connected to a SPAN or TAP output. These ports are named (from right to left) if3, if4, if5 and if6.
Dimensions
Width: 430.0mm (19 inch)
Hight: 86.8mm (2U)
Depth: 715.5mm
Weight
Without rails 29kg
Including sliding rails and cable management 32kg
Power and heat
PSU (Power): 2x 1100W (ISO/IEC320 C14 connector)
Maximum heat dissipation: 4100BTU/h
Frequency: 50Hz
Voltage: 240V AC
Maximum current: 6.5A
Measured power consumption: 500W maximum, 350W average (both PSU cabled and active)
Accessories
2x ISO/IEC320 C13/C14 cable
1x pair of sliding rails
1x cable management arm
In accordance with COMCERT Durability Procedures, unwanted accessories may be returned to COMCERT for re-use.