== Introduction ==
== Introduction ==


Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords. Test reference cords have a much lower insertion loss in comparison to off the shelf patch cords. Furthermore, test reference cords and the 1-jumper reference should be used to ensure maximum test accuracy. The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes with all accesories needed to test LC-to-LC fiber optic links.
Loss/length testing in accordance to ISO/IEC 14763-3:2014 requires the use of Test Reference Cords (TRC). TRC have better Insertion Loss (IL) performance in comparison to standard patch cords. Furthermore, TRC and the 1-jumper reference should be used to ensure maximum test accuracy and is required by the majority of fiber optic manufacturers.  Depending on the kit you bought, the CertiFiber Pro comes with TRC and adapters required to test LC-to-LC multi-mode and singlemode fiber optic links.  In cases where you need to test not only LC-to-LC but also SC-to-SC or SC-to-LC fiber optic links, you need to purchase accessories.


 
 
Line 8: Line 8:
== Solution ==
== Solution ==


=== Accessories ===
=== Fluke Networks Accessories ===


In those cases where you need to test not only LC-to-LC but also SC-to-SC and SC-to-LC fiber optic links, you need to purchase the accessories listed below.
In those cases where you need to test not only LC-to-LC but also SC-to-SC or SC-to-LC fiber optic links, you need to purchase accessories.


Further information on how to use these accessories will be explained during our Certified Cable Test Training VERSIVFO module.
Detailed  information on how to use these accessories is or will be explained during the Certified Cable Test Training VERSIVFO module.


{| border="1" cellpadding="1" cellspacing="1" style="width: 1200px;"
{| border="1" cellpadding="1" cellspacing="1" style="width: 1200px;"
|-
|-
| style="width: 61px;" | Product
| style="width: 61px;" | Product
| style="width: 156px;" | Model
| style="width: 197px;" | Model
| style="width: 287px;" | Description
| style="width: 300px;" | Description
| style="width: 178px;" | Included with tester
| style="width: 124px;" | Included with tester
| style="width: 244px;" | Required for testing (LC-to-LC and SC-to-SC)
| style="width: 244px;" | Needed for testing (LC-to-LC and SC-to-SC)
| style="width: 241px;" | Required for testing (LC-to-LC, SC-to-SC and LC-to-SC)
| style="width: 241px;" | Needed for testing (LC-to-LC, SC-to-SC and LC-to-SC)
|-
|-
| style="width: 61px;" |  
| style="width: 61px;" |  
2635934
2635934


| style="width: 156px;" | NFA-LC
| style="width: 197px;" | NFA-LC
| style="width: 287px;" | Set of LC Test Adapters (2)
| style="width: 300px;" | Set of LC Test Adapters (2)
| style="width: 178px;" | 1
| style="width: 124px;" | 1
| style="width: 244px;" | 1
| style="width: 244px;" | 1
| style="width: 241px;" | 1
| style="width: 241px;" | 1
|-
|-
| style="width: 61px;" | 4320262
| style="width: 61px;" | 4320262
| style="width: 156px;" | MRC-50EFC-SCLCKIT (*)
| style="width: 197px;" | MRC-50EFC-SCLCKIT (*)
| style="width: 287px;" | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm LC Fibers
| style="width: 300px;" | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm LC Fibers
| style="width: 178px;" | 1
| style="width: 124px;" | 1
| style="width: 244px;" | 1
| style="width: 244px;" | 1
| style="width: 241px;" | 2
| style="width: 241px;" | 2
|-
|-
| style="width: 61px;" | 4335564
| style="width: 61px;" | 4335564
| style="width: 156px;" | SRC-9-SCLC-KIT (*)
| style="width: 197px;" | SRC-9-SCLC-KIT (*)
| style="width: 287px;" | Singlemode Test Reference Cord (TRC) Kit, 2m, (2) SC/LC, (2) LC/LC
| style="width: 300px;" | Singlemode Test Reference Cord (TRC) Kit, 2m, (2) SC/LC, (2) LC/LC
| style="width: 178px;" | 1
| style="width: 124px;" | 1
| style="width: 244px;" | 1
| style="width: 244px;" | 1
| style="width: 241px;" | 2
| style="width: 241px;" | 2
Line 49: Line 49:
2635929
2635929


| style="width: 156px;" | NFA-SC
| style="width: 197px;" | NFA-SC
| style="width: 287px;" | SC Test Adapter Set of Two
| style="width: 300px;" | SC Test Adapter Set of Two
| style="width: 178px;" | 0
| style="width: 124px;" | 0
| style="width: 244px;" | 1
| style="width: 244px;" | 1
| style="width: 241px;" | 1
| style="width: 241px;" | 1
|-
|-
| style="width: 61px;" | 4322705
| style="width: 61px;" | 4322705
| style="width: 156px;" | MRC-50EFC-SCSCKIT (*)
| style="width: 197px;" | MRC-50EFC-SCSCKIT (*)
| style="width: 287px;" | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm SC Fibers
| style="width: 300px;" | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm SC Fibers
| style="width: 178px;" | 0
| style="width: 124px;" | 0
| style="width: 244px;" | 1
| style="width: 244px;" | 1
| style="width: 241px;" | 1
| style="width: 241px;" | 1
|-
|-
| style="width: 61px;" | 4334464
| style="width: 61px;" | 4334464
| style="width: 156px;" | SRC-9-SCSC-KIT (*)
| style="width: 197px;" | SRC-9-SCSC-KIT (*)
| style="width: 287px;" | Singlemode Test Reference Cord (TRC) Kit, 2m, (4) SC/SC
| style="width: 300px;" | Singlemode Test Reference Cord (TRC) Kit, 2m, (4) SC/SC
| style="width: 178px;" | 0
| style="width: 124px;" | 0
| style="width: 244px;" | 1
| style="width: 244px;" | 1
| style="width: 241px;" | 1
| style="width: 241px;" | 1
|}
|}


(*) consumable:
(*) Consider this being a consumable! In accordance to ISO/IEC 61300-2-2, the mechanical endurance (durability) of the connecting hardware shall be ≥500 cycles:


LC between 500-1000 test cycles
*LC lifecycle typical between 500 and 1000 cycles
*SC lifecycle typical over 1000 cycles  


SC between 2000-5000 test cycles
TRC and adapters are available for all other connector types with the exception of 9° LC/APC and 9° SC/APC.  Those types are available from COMCERT.  Please consult you FNET distributor for more information and a quote.
 
 


 
 


 
 

Latest revision as of 07:21, 8 May 2021

Introduction

Loss/length testing in accordance to ISO/IEC 14763-3:2014 requires the use of Test Reference Cords (TRC). TRC have better Insertion Loss (IL) performance in comparison to standard patch cords. Furthermore, TRC and the 1-jumper reference should be used to ensure maximum test accuracy and is required by the majority of fiber optic manufacturers.  Depending on the kit you bought, the CertiFiber Pro comes with TRC and adapters required to test LC-to-LC multi-mode and singlemode fiber optic links.  In cases where you need to test not only LC-to-LC but also SC-to-SC or SC-to-LC fiber optic links, you need to purchase accessories.

 

Solution

Fluke Networks Accessories

In those cases where you need to test not only LC-to-LC but also SC-to-SC or SC-to-LC fiber optic links, you need to purchase accessories.

Detailed  information on how to use these accessories is or will be explained during the Certified Cable Test Training VERSIVFO module.

Product Model Description Included with tester Needed for testing (LC-to-LC and SC-to-SC) Needed for testing (LC-to-LC, SC-to-SC and LC-to-SC)

2635934

NFA-LC Set of LC Test Adapters (2) 1 1 1
4320262 MRC-50EFC-SCLCKIT (*) Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm LC Fibers 1 1 2
4335564 SRC-9-SCLC-KIT (*) Singlemode Test Reference Cord (TRC) Kit, 2m, (2) SC/LC, (2) LC/LC 1 1 2

2635929

NFA-SC SC Test Adapter Set of Two 0 1 1
4322705 MRC-50EFC-SCSCKIT (*) Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm SC Fibers 0 1 1
4334464 SRC-9-SCSC-KIT (*) Singlemode Test Reference Cord (TRC) Kit, 2m, (4) SC/SC 0 1 1

(*) Consider this being a consumable! In accordance to ISO/IEC 61300-2-2, the mechanical endurance (durability) of the connecting hardware shall be ≥500 cycles:

  • LC lifecycle typical between 500 and 1000 cycles
  • SC lifecycle typical over 1000 cycles

TRC and adapters are available for all other connector types with the exception of 9° LC/APC and 9° SC/APC.  Those types are available from COMCERT.  Please consult you FNET distributor for more information and a quote.