NSE-12 and NSE-22 quick start guide: Difference between revisions
No edit summary |
No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
== Introduction == | == Introduction == | ||
Network Service Element | Network Service Element is available in two configurations and two storage sizes, respectively SPAN and TAP and 500GB and 2TB. | ||
The SPAN model has two independent monitor interfaces labeled LAN 3 and LAN 4. In a typical configuration, both ports will be connected to two SPAN output ports: one port representing all packets from the network to the site and the other port representing all packets in the opposite direction. The NSE offers great WAN visibility, including a more precise traffic measurements method than possible with flow based analysis or snmp. Other applications of NSE are possible, for example the monitoring of server bound traffic in a relatively small remote datacenter. | The SPAN model has two independent monitor interfaces labeled LAN 3 and LAN 4. In a typical configuration, both ports will be connected to two SPAN output ports: one port representing all packets from the network to the site and the other port representing all packets in the opposite direction. The NSE offers great WAN visibility, including a more precise traffic measurements method than possible with flow based analysis or snmp. Other applications of NSE are possible, for example the monitoring of server bound traffic in a relatively small remote datacenter. | ||
Line 26: | Line 26: | ||
Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600, 8N1, no flow control. | Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600, 8N1, no flow control. | ||
| |||
=== Running commands === | |||
User Administrator has restricted access to the appliance and can only run a predefined set of commands as user root (sudo). Please remember to add "sudo" in front of the classical nGenius commands. | |||
Example: | |||
<code>./PS</code> will become <code>sudo ./PS</code> | |||
<code>./localconsole</code> will become <code>sudo ./localconsole</code> | |||
<code>systemctl restart vstream</code> will become <code>sudo systemctl restart vstream</code> | |||
| | ||
Line 49: | Line 63: | ||
| | ||
{{#invoke:Message box|ambox |type=warning|text=Power-off is the equivalent of removing the power cable from the appliance and it may cause data loss. | {{#invoke:Message box|ambox |type=warning|text=Power-off is the equivalent of removing the power cable from the appliance and it may cause data loss. Use only when restart and shutdown fails.}} | ||
| |
Latest revision as of 07:47, 14 August 2020
Introduction
Network Service Element is available in two configurations and two storage sizes, respectively SPAN and TAP and 500GB and 2TB.
The SPAN model has two independent monitor interfaces labeled LAN 3 and LAN 4. In a typical configuration, both ports will be connected to two SPAN output ports: one port representing all packets from the network to the site and the other port representing all packets in the opposite direction. The NSE offers great WAN visibility, including a more precise traffic measurements method than possible with flow based analysis or snmp. Other applications of NSE are possible, for example the monitoring of server bound traffic in a relatively small remote datacenter.
The fail-safe TAP model has been designed to be installed inline between the CPE and the local switch. No specific configuration of those devices is required.
Solution
Connect to the appliance
The appliance is accessible through ssh using a terminal emulator program and via a serial console located on the back of the appliance. It ships with two local user accounts, Administrator and comcert. User Administrator has been created to be used by the end-user to safely shut-down and reboot the appliance. User comcert is reserved for COMCERT Support (C-TAC).
Using a computer or terminal:
From a computer running Windows: use a recent version of a program such as MobaXterm or Putty to connect to NSE.
From a computer running Linux: to connect to NSE, run the following command:
ssh -l Administrator <IPaddressPMA>
Using the serial console:
Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600, 8N1, no flow control.
Running commands
User Administrator has restricted access to the appliance and can only run a predefined set of commands as user root (sudo). Please remember to add "sudo" in front of the classical nGenius commands.
Example:
./PS
will become sudo ./PS
./localconsole
will become sudo ./localconsole
systemctl restart vstream
will become sudo systemctl restart vstream
Shutdown and reboot the appliance
All applications must be brought-down properly before shutting-down or rebooting the appliance. Failure to do so may result in loss of recorded data. |
Connect to NSE and login as Administrator.
Once authenticated, run one of the following commands:
To restart the appliance:
$ nse-restart
To shut-down the appliance:
$ nse-shutdown
Power-off is the equivalent of removing the power cable from the appliance and it may cause data loss. Use only when restart and shutdown fails. |
To power-off the appliance forcefully:
$ nse-poweroff