Revision as of 15:07, 15 September 2017

Introduction

The limits stipulated in ISO1801 are not longer usable to evaluate the quality of a recently installed fiber optic link.  They are too relaxed.

These values are not applicable when testing links containing MPO connectors.

 

Solution

We recommend the useof this custom limit for OTDR event evaluation. More context will be given during the Certified Cabling Test Training module VERSIVOTDR.

Parameter Default value Recommended value
Length (m) N/A N/A