CertiFiber Pro custom test limit: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
| | ||
== Solution == | == Solution == | ||
Line 20: | Line 21: | ||
| Length (m) | | Length (m) | ||
| 2000,0 | | 2000,0 | ||
| 2000,0 | | 2000,0 | ||
|- | |- | ||
| Connection Loss (dB) | | Connection Loss (dB) | ||
Line 46: | Line 47: | ||
| 1,00 | | 1,00 | ||
|} | |} | ||
Revision as of 15:04, 15 September 2017
Introduction
The limits stipulated in ISO1801 are not longer usable to evaluate the quality of a recently installed fiber optic link. They are too relaxed.
These values are not applicable when testing links containing MPO connectors.
Solution
We recommend the useof this custom limit for length/loss testing. More context will be given during the Certified Cabling Test Training module VERSIVFO.
Parameter | Default value | Recommended value |
Length (m) | 2000,0 | 2000,0 |
Connection Loss (dB) | 0,75 | 0,30 |
Splice Loss (dB) | 0,30 | 0,15 |
Loss/km @ 850nm (dB/km) | 3,00 | 3,00 |
Loss/km @ 1300nm (dB/km) | 1,50 | 1,50 |
Loss/km @ 1310nm (dB/km) | 1,00 | 1,00 |
Loss/km @ 1550nm (dB/km) | 1,00 | 1,00 |