CertiFiber Pro custom test limit: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 2: Line 2:
== Introduction ==
== Introduction ==


The limits stipulated in ISO1801 are not longer usable to evaluate the quality of a recently installed fiber optic link.  They are too relaxed.  
It is our opinion that the lenght/loss limit specified in ISO/IEC 18011:2010 is not longer adequate to evaluate the quality of a recently installed fiber optic link; they are too relaxed.
 
These values are not applicable when testing links containing MPO connectors.


 
 
Line 10: Line 8:
== Solution ==
== Solution ==


We recommend the use of this custom limit for length/loss testing.
We recommend the use of this custom limit for length/loss. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit.  For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More context is available during the Certified Cabling Test Training module VERSIVFO.
 
More context will be given during the Certified Cabling Test Training module VERSIVFO.


{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"

Revision as of 05:17, 16 September 2017

Introduction

It is our opinion that the lenght/loss limit specified in ISO/IEC 18011:2010 is not longer adequate to evaluate the quality of a recently installed fiber optic link; they are too relaxed.

 

Solution

We recommend the use of this custom limit for length/loss. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit.  For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More context is available during the Certified Cabling Test Training module VERSIVFO.

Parameter Default value Recommended value
Length (m) 2000,0 2000,0
Connection Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Loss/km @ 850nm (dB/km) 3,00 3,00
Loss/km @ 1300nm (dB/km) 1,50 1,50
Loss/km @ 1310nm (dB/km) 1,00 1,00
Loss/km @ 1550nm (dB/km) 1,00 1,00