Configuring flow export: Difference between revisions
No edit summary |
No edit summary |
||
Line 90: | Line 90: | ||
| | ||
Basically, this is the science of deploying sensors so that <span style="background-color:#FFFF00 | Basically, this is the science of deploying sensors so that <span style="background-color:#FFFF00">EVERY flow that goes through the FED is metered</span>. It is equally important to make sure that <span style="background-color:#FFFF00">NO flow is metered more than once</span>. | ||
<u>Example 1</u>: Ingress/in sensor on both interfaces. Flows from user to network are metered by the sensor on interface 0/0 while flows from network to user are metered by the sensor on interface 0/1. | <u>Example 1</u>: Ingress/in sensor on both interfaces. Flows from user to network are metered by the sensor on interface 0/0 while flows from network to user are metered by the sensor on interface 0/1. | ||
Line 118: | Line 118: | ||
| | ||
This is how a Flexible NetFlow configuration would look like on a CISCO 3800 Series router with a recent IOS. The router has two physical interfaces facing the network (WAN). | This is how a Flexible NetFlow configuration would look like on a CISCO 3800 Series router with a recent IOS. The router has two physical interfaces facing the network (WAN) with different capacity. There is no traffic between these interfaces. Please note that in most cases the collector needs to be able to query the router by SNMP in order to "discover" its interface configuration and hostname. You may need to configure the capacity of the interfaces (bps) to the collector/reporter manually to allow correct calculation of interface utilization (%). | ||
| |||
<pre>ip access-list standard SNMP-NS | <pre>ip access-list standard SNMP-NS | ||
permit 10.200.255.123 | permit 10.200.255.123 | ||
Line 124: | Line 126: | ||
! | ! | ||
! | ! | ||
flow record record- | flow record record-comcert | ||
match ipv4 tos | match ipv4 tos | ||
match ipv4 protocol | match ipv4 protocol | ||
Line 132: | Line 134: | ||
match transport destination-port | match transport destination-port | ||
match interface input | match interface input | ||
match interface output | match interface output | ||
collect transport tcp flags | collect transport tcp flags | ||
collect counter bytes long | collect counter bytes long | ||
collect counter packets long | collect counter packets long | ||
collect timestamp | collect timestamp sys-uptime first | ||
collect timestamp | collect timestamp sys-uptime last | ||
! | ! | ||
! | ! | ||
flow exporter comcert | flow exporter exporter-comcert | ||
destination 10.200.255.123 | destination 10.200.255.123 | ||
source Vlan1301 | source Vlan1301 | ||
Line 162: | Line 150: | ||
! | ! | ||
! | ! | ||
flow monitor monitor- | flow monitor monitor-comcert | ||
exporter comcert-1 | exporter comcert-1 | ||
cache timeout active 60 | cache timeout active 60 | ||
cache timeout inactive 14 | cache timeout inactive 14 | ||
record record- | record record-comcert | ||
! | ! | ||
! | ! | ||
interface GigabitEthernet1/1/1 | interface GigabitEthernet1/1/1 | ||
bandwidth 20000 | bandwidth 20000 | ||
ip flow monitor monitor- | ip flow monitor monitor-comcert input | ||
ip flow monitor monitor- | ip flow monitor monitor-comcert output | ||
! | ! | ||
! | ! | ||
interface GigabitEthernet2/1/1 | interface GigabitEthernet2/1/1 | ||
bandwidth 10000 | |||
ip flow monitor monitor- | ip flow monitor monitor-comcert input | ||
ip flow monitor monitor- | ip flow monitor monitor-comcert output | ||
</pre> | </pre> |
Revision as of 16:40, 21 September 2018
Introduction
Proper configuration of Flow Exporting Devices (FED) is key to Flow Based Network Analysis. Errors made during configuration will result in missing or duplicate data and are difficult to identify. Vendors of network equipment are not making it easy as most of them are using a proprietary method to enable flow exports to the collector (in our case TVF or TVA).
Furthermore, some collectors require special configuration to be made on the FED in order to undersand its flows correctly.
This article is trying to decribe the concept behind network flow reporting and we hope it will help you to determine the correct procedure on how to confgure your FEDs.
For a complete overview of IP Flow Information eXchange (IPFIX), we recommend the reading of RFC 3917.
If you come aware of vendor specific issues during the configuration please let us know.
Solution
Definitions
FED
A Flow Enabled Device is in general any L3 device sending flow records to a collector.
Flow
A flow is defined as a stream of packets between a given source and a given destination. For example, in client-server computing a TCP sessions consists of two flows: one flow from client to server and the second flow from server to client.
Flow record
A flow record contains information about a specific flow that was metered at an observation point. A flow record contains measured properties of the flow (e.g., the total number of bytes of all packets of the flow, flow duration and the physical or virtual input interface i.e. where the packets entered the FED) and usually characteristic properties of the flow (e.g., source/destination IP address, protocol, port, ToS/DiffServ marking, ...).
Sensor
A sensor is a meter located at an observation point. It will "meter" the packets going by the observation point and "build" the flow record decribing the flow. A sensor will meter packets in one direction only (inwards/ingress/in or outwards/egress/out) but some vendors use sensors that are bidirectional.
Collector
A flow collector is most likely a server or appliance that collects the flow records and stores them in a database-like structure. In a TruView system , TruView Flow is the collector.
Reporter
The reporter is an application running on the same or a different server than the collector that mines the data records and produces statistical results. In a TruView system, TruView Central is the reporter.
Global configuration
The way to enable flow monitoring and flow exports will vary from vendor to vendor. At large you have to configure these parameters:
Destination
- IP address of the collector
Port
- UDP port where the collector is listening on
Active flow timeout
- Interval at which flow record updates are send in case of long flows. A flow is considered long when it exceeds the smallest database granularit. Consequently, this setting should match the smallest granularity of the database on the collector. In case of TruView, this is one minute
Inactive flow timeout
- Interval of inactivity (no packets) that marks a flow as inactive. The recommended setting is 15 seconds.
Flow record format
With the introduction of CISCO's Flexible NetFlow and the standardization of IPFIX, the PDU of a flow record is no longer uniformely defined. The fields contained in the PDU should reflect the reporter's capabilities. In case of TruView the flow record must contain at least the following information:
- source address
- destination addresstos
- protocol
- source port
- destination port
- input interface
- tcp flags
- number of bytes
- number of packets
- timestamp of the first packet of the flow
- timestamp of the last packet of the flow
Interface configuration examples
If this is your first experience with configuring flow export on network devices, we recommend you make a drawing of the device, its interfaces (physical and virtual) and every flow that goes through the device. |
Basically, this is the science of deploying sensors so that EVERY flow that goes through the FED is metered. It is equally important to make sure that NO flow is metered more than once.
Example 1: Ingress/in sensor on both interfaces. Flows from user to network are metered by the sensor on interface 0/0 while flows from network to user are metered by the sensor on interface 0/1.
Example 2: egress/out sensor on both interfaces. Flow from user to network are metered by the sensor on interface 0/1 while flows from network to user are metered by the sensor on interface 0/0.
Example 3: combination of ingress/in and egress/out sensors. Flows from user to network are metered by the ingress/in sensor on interface 0/0. Flows from network to user are metered by the egress/out sensor on that same interface 0/0. This configuration is prefrerable when interface 0/1 is complex like a multitude of virtual interfaces or/and encrypted tunnels.
Example 4: combination of ingress/in and egress/out sensors. Flows from user to network are metered by the egress/out sensor on interface 0/1. Flows from network to user are metered by the ingress/in sensor on that same interface 0/1. This configuration is likely when an operator configures flow export as the operator only cares about the network side of the router (interface 0/1). It can also be applied when the user side of the router is complex.
Cisco configuration example
This is how a Flexible NetFlow configuration would look like on a CISCO 3800 Series router with a recent IOS. The router has two physical interfaces facing the network (WAN) with different capacity. There is no traffic between these interfaces. Please note that in most cases the collector needs to be able to query the router by SNMP in order to "discover" its interface configuration and hostname. You may need to configure the capacity of the interfaces (bps) to the collector/reporter manually to allow correct calculation of interface utilization (%).
ip access-list standard SNMP-NS permit 10.200.255.123 snmp-server community c0mc3rt-ro RO SNMP-NS ! ! flow record record-comcert match ipv4 tos match ipv4 protocol match ipv4 source address match ipv4 destination address match transport source-port match transport destination-port match interface input match interface output collect transport tcp flags collect counter bytes long collect counter packets long collect timestamp sys-uptime first collect timestamp sys-uptime last ! ! flow exporter exporter-comcert destination 10.200.255.123 source Vlan1301 transport udp 2055 template data timeout 60 option sampler-table timeout 60 ! ! flow monitor monitor-comcert exporter comcert-1 cache timeout active 60 cache timeout inactive 14 record record-comcert ! ! interface GigabitEthernet1/1/1 bandwidth 20000 ip flow monitor monitor-comcert input ip flow monitor monitor-comcert output ! ! interface GigabitEthernet2/1/1 bandwidth 10000 ip flow monitor monitor-comcert input ip flow monitor monitor-comcert output