Introduction

To minimize the risk of data loss, it is recommended that all services are stopped before restarting or shutting down the machine.

 

Solution

nGeniusPULSE (version 2.5 and above)

  • Connect to the host using an SSH client of your choice
  • Login as nGPadmin (for default credentials read default credentials)
  • Change to the folder /opt/ipm/appliance/
# cd /opt/ngp/appliance/

To restart all relevant services without restarting the applicance

  • Execute the stop script, followed by the start script
# ./ngp-stop-services.sh
# ./ngp-start-services.sh

To restart the applicance

  • Execute the stop script, followed by shutdown -r
# ./ngp-stop-services.sh
# shutdown -r now

To shutdown the applicance

  • Execute the stop script, followed by shutdown -h
# ./ngp-stop-services.sh
# shutdown -h now