Gracefull shutdown/restart nGeniusPULSE: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 16: | Line 16: | ||
</pre> | </pre> | ||
==== To restart all services without restarting the applicance ==== | ==== To restart all relevant services without restarting the applicance ==== | ||
*Execute the stop script, followed by the start script | *Execute the stop script, followed by the start script |
Revision as of 08:35, 4 June 2018
Introduction
To minimize the risk of data loss, it is recommended that all services are stopped before restarting or shutting down the machine.
Solution
nGeniusPULSE (version 2.5 and above)
- Connect to the host using an SSH client of your choice
- Login as nGPadmin (for default credentials read default credentials)
- Change to the folder /opt/ipm/appliance/
# cd /opt/ngp/appliance/
To restart all relevant services without restarting the applicance
- Execute the stop script, followed by the start script
# ./ngp-stop-services.sh # ./ngp-start-services.sh
To restart the applicance
- Execute the stop script, followed by shutdown -r
# ./ngp-stop-services.sh # shutdown -r now
To shutdown the applicance
- Execute the stop script, followed by shutdown -h
# ./ngp-stop-services.sh # shutdown -h now