OptiFiber Pro custom test limit: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 2: Line 2:
== Introduction ==
== Introduction ==


Length/loss limits to be used with ISO/IEC14763-3:2014 (Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling) are no longer adequate to evaluate the quality of a recent installed fiber optic infrastructure as they are too relaxed.
Limits specified by ISO/IEC11801:2017 and ISO/IEC14763-3:2014 (Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling) are no longer adequate to evaluate the quality of recently installed fiber optic infrastructure.
 
This article was recently updated for firmware version 6.0 (January 2019).


 
 
Line 8: Line 10:
== Solution ==
== Solution ==


We recommend this custom limit during OTDR testing. End-users could set a Maximum Length and Maximum Overall Loss in accordance with the application limit.  For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More information is available during the Certified Cabling Test Training module VERSIVOTDR.
Create the following custom limit for OTDR testing. More information is available during the Certified Cabling Test Training module VERSIVOTDR.
 
Limits that are not mentionned in this table are kept default.
 
 
 


=== Maximum length ===
=== Maximum length ===


{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
{| style="width: 500px" cellspacing="1" cellpadding="1" border="1"
|-
|-
| Parameter
| Parameter
Line 22: Line 29:
| N/A
| N/A
|}
|}
 
General Settings
 


 
 
Line 27: Line 40:
=== Limits for 850 nm ===
=== Limits for 850 nm ===


{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
{| style="width: 500px" cellspacing="1" cellpadding="1" border="1"
|-
|-
| Parameter
| Parameter
Line 62: Line 75:
=== Limits for 1300 nm ===
=== Limits for 1300 nm ===


{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
{| style="width: 500px" cellspacing="1" cellpadding="1" border="1"
|-
|-
| Parameter
| Parameter
Line 97: Line 110:
=== Limits for 1310 nm ===
=== Limits for 1310 nm ===


{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
{| style="width: 500px" cellspacing="1" cellpadding="1" border="1"
|-
|-
| Parameter
| Parameter
Line 134: Line 147:
=== Limits for 1550 nm ===
=== Limits for 1550 nm ===


{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
{| style="width: 500px" cellspacing="1" cellpadding="1" border="1"
|-
|-
| Parameter
| Parameter

Revision as of 17:15, 12 January 2019

Introduction

Limits specified by ISO/IEC11801:2017 and ISO/IEC14763-3:2014 (Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling) are no longer adequate to evaluate the quality of recently installed fiber optic infrastructure.

This article was recently updated for firmware version 6.0 (January 2019).

 

Solution

Create the following custom limit for OTDR testing. More information is available during the Certified Cabling Test Training module VERSIVOTDR.

Limits that are not mentionned in this table are kept default.

 


Maximum length

Parameter Default value Recommended value
Length (m) N/A N/A

 

General Settings

 

 

Limits for 850 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Reflectance (dB) -35,0 -35,0
Overall Loss (dB) N/A N/A
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 3,00

 

Limits for 1300 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Reflectance (dB) -35,0 -35,0
Overall Loss (dB) N/A N/A
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 1,50

 

Limits for 1310 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15 (UPC) or 0.30 (APC)*
Reflectance (dB) -45,0 -45,0
Overall Loss (dB) N/A N/A
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 1,00

(*) When testing APC terminated fibers, the OTDR will interpret the APC connection as a splice and apply the splice limit accordingly.  In case of APC terminated fiber, we recommend using the same limit for connection and splice i.e. 0.30dB.

 

Limits for 1550 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15 (UPC) or 0.30 (APC)*
Reflectance (dB) -45,0 -45,0
Overall Loss (dB) N/A N/A
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 1,00

(*) When testing APC terminated fibers, the OTDR will interpret the APC connection as a splice and apply the splice limit accordingly.  In case of APC terminated fiber, we recommend using the same limit for connection and splice i.e. 0.30dB.