Introduction

Many fiber optic technicians are unfamiliar working with logarithmic units like decibel (dB).

This table allows you to get a grasp on the relationship between loss on a logartimic scale (dB) and optical power reduction on a liniar scale (%).

 

Solution

 

Attenuation Optical Power Reduction
0 dB 0%
1 dB 21%
2 dB 37%
3 dB 50%
4 dB 60%
5 dB 68%
6 dB 75%
7 dB 80%
10 dB 90%
13 dB 95%
15 dB 96.8%