<u>All models:</u> | |||
LAN 1: MANagement port: this port must be connected to a local switchport. | |||
LAN 2: not connected. | |||
LAN 5: (SFP not present), not connected. | |||
LAN 6: (SFP not present), not connected. | |||
<u>SPAN model:</u> | |||
LAN 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*. | |||
LAN 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*. | |||
<u>TAP model (inline):</u> | |||
Install the appliance between the WAN Access Device and the local switch. Connect LAN3 to the WAN access device and LAN4 to the local switch. The applicance does not provide PoE. | |||
(*) See configuration examples for Alcatel Lucent | (*) See configuration examples for Alcatel Lucent |
Revision as of 14:14, 11 August 2020
Network connections (appliance rear view)
This picture shows the minimal set of ports that must be connected in order to operate normally. More connections ma required
All models:
LAN 1: MANagement port: this port must be connected to a local switchport.
LAN 2: not connected.
LAN 5: (SFP not present), not connected.
LAN 6: (SFP not present), not connected.
SPAN model:
LAN 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*.
LAN 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*.
TAP model (inline):
Install the appliance between the WAN Access Device and the local switch. Connect LAN3 to the WAN access device and LAN4 to the local switch. The applicance does not provide PoE.
(*) See configuration examples for Alcatel Lucent
(*) See configuration examples for Cisco
System dimensions
Width: 220mm (without mounting brackets) 430mm (with 19" mounting brachets)
Hight: 44mm
Depth: 105mm
Weight
kg (without mounting brackets)
PSU specifications
PSU (Power): External power supply (IEC320 C14 connector)
Maximum heat dissipation:
Frequency: 50Hz - 60Hz
Voltage: 100V - 240V AC
Maximum current: 1.5A
Power based on observation:
Operating parameters
Temperature: 0°C - 40°C
Humidity: 10% - 80% RH non-condensing
Vibration: 0.5Grms / 5Hz ~ 500Hz
Shock: 10G