NSE-12 and NSE-22 quick start guide: Difference between revisions
No edit summary |
No edit summary |
||
Line 18: | Line 18: | ||
==== Using the network and ssh: ==== | ==== Using the network and ssh: ==== | ||
Windows: | From a computer running Windows: use a recent version of a program such as MobaXterm or Putty to connect to NSE. | ||
From a computer running Linux: to connect to NSE, run the following command: | |||
<pre>ssh -l Administrator <IPaddressPMA></pre> | <pre>ssh -l Administrator <IPaddressPMA></pre> | ||
Using the serial console: | ==== Using the serial console: ==== | ||
Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600, 8N1, no flow control. | Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600, 8N1, no flow control. |
Revision as of 07:48, 13 August 2020
Introduction
Network Service Element come in two varieties: SPAN and TAP.
The SPAN model has two independent monitor interfaces labeled LAN 3 and LAN 4. In a typical configuration, both ports will be connected to two SPAN output ports: one port representing all packets from the network to the site and the other port representing all packets in the opposite direction. The NSE offers great WAN visibility, including a more precise traffic measurements method than possible with flow based analysis or snmp. Other applications of NSE are possible, for example the monitoring of server bound traffic in a relatively small remote datacenter.
The fail-safe TAP model has been designed to be installed inline between the CPE and the local switch. No specific configuration of those devices is required.
Solution
Connect to the appliance
The appliance is accessible through ssh using a terminal emulator program and via a serial console located on the back of the appliance. It ships with two local user accounts, Administrator and comcert. User Administrator has been created to be used by the end-user to safely shut-down and reboot the appliance. User comcert is reserved for COMCERT Support (C-TAC).
Using the network and ssh:
From a computer running Windows: use a recent version of a program such as MobaXterm or Putty to connect to NSE.
From a computer running Linux: to connect to NSE, run the following command:
ssh -l Administrator <IPaddressPMA>
Using the serial console:
Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600, 8N1, no flow control.
Shutdown and reboot the appliance
All applications must be brought-down properly before shutting-down or rebooting the appliance. Failure to do so may result in loss of recorded data. |
Connect to NSE and login as Administrator.
Once authenticated, run one of the following commands:
To shut-down the appliance:
$ sudo systemctl halt
To reboot the appliance:
$ sudo systemctl reboot
Use Power-Off only when all the above commands fail. This command is the equivalent of removing the power cable |
To power-off the appliance:
$ sudo systemctl poweroff