Infinistream socket table: Difference between revisions
No edit summary |
No edit summary |
||
Line 59: | Line 59: | ||
% set skt 12 tran_count 16000000 | % set skt 12 tran_count 16000000 | ||
</pre> | </pre> | ||
In a similar fashion the values of the ASR tables can be adjusted. | |||
First, verify the current settings: | |||
<pre>% get xdr | |||
</pre> | |||
First, the verify the maximum value that can be configured for that table: | |||
| |||
| |||
| |
Revision as of 15:36, 27 January 2023
LET OP, ARTIKEL IS NIET VOLLEDIG HET IS NIET DUIDELIJK WAT "tupple=on" PRECIES DOET
Summary
In situations that the summary pane of a monitor show data, but drilling down towards the session pane results in "No data available" you might run into overloaded database tables. This article shows how to verify if the Infinistream is suffering from this problem.
Procedure
Verification
Log into the Infinistream and launch a localconsole session:
# isbin # ./localconsole
Now, enter command-line mode by typing 11 and proceed with the following command:
% get dump tables
Search for the lines skt_trans and skt_table. The last column of these lines show if drops were seen.
Altering the table configuration
The first step is altering the file .afm_mode. This file is located in /opt/Netscout/rtm/bin
# isbin # vi .afm_mode
And append the following line tupple=on
Check the configuration of the socket table:
% get skt
Three parameters can be adjusted:
- age interval
- table size
- tran_count
The default value for age interval is 180 seconds. Reduce the ageout interval in the skt tables (from localconsole CLI) - since modern transactions should be completed very quickly, having an 180-second limit is well beyond the range of what would be considered a "timeout", so having the "ageout" limit of 180-seconds means we store too many entries that should expire from this table. Reducing this ageout value means the table will be cleared faster to allow for more/newer entries to be created.
% set skt 12 age_interval 30
The maximum table size and transaction count depend on the amount of RAM that is installed in the Infinistream. Entering an unrealistic low value will result in a response that informs us about the maximum value for this specific system.
% set skt 12 table 5 % set skt 12 tran_count 5
Now, the maximum value will become visible on the screen.
As a best practice we will configure 50% of the maximum value returned by "set skt 12 table 5"
For example if the returned value is 32000000, increase the size of the socket table to allow for more traffic:
% set skt 12 table 16000000 % set skt 12 tran_count 16000000
In a similar fashion the values of the ASR tables can be adjusted.
First, verify the current settings:
% get xdr
First, the verify the maximum value that can be configured for that table: