Introduction
This is an extract of the most recent publication of the standard ISO/IEC 14763-3 in 2024. Information technology - Implementation and operation of customer premises cabling - Part 3: Testing of optical fiber cabling. To purchase the publication, please visit ISO Store.
Solution
Table
Cable type* | Adapter loss embedded (dB) | Adapter loss first and last (dB) | Splice loss | Fiber loss @ 850nm (dB/km) | Fiber loss @ 1300nm (dB/km) | Fiber loss @ 1310nm (dB/km) | Fiber loss @ 1550nm (dB/km) | Length (m) |
---|---|---|---|---|---|---|---|---|
OS1/OS1a | 0.75 | 0.7 | 0.3 | - | - | 1.0 | 1.0 | 5000 |
OS2 | 0.75 | 0.7 | 0.3 | - | - | 0.4 | 0.4 | 5000 |
OM1, OM2, OM3, OM4, OM5 | 0.75 | 0.45 | 0.3 | 3.5 | 1.5 | - | - | 2000 |
Examples
Example 1 - Multi-mode channel
Consider a cabling channel comprising:
• optical fiber conforming to OM4 of ISO/IEC 11801-1;
• a total length including equipment cords of 100 m;
• two panel connections in accordance with ISO/IEC 11801-1;
• equipment cords terminated with connectors in accordance with ISO/IEC 11801-1.
The channel limit at 850 nm would be: (0,1 × 3,5 dB) + (2 × 0,75 dB) = 1,85 dB
The channel limit at 1 300 nm would be: (0,1 × 1,5 dB) + (2 × 0,75 dB) = 1,65 dB
Example 2 - Single-mode channel
Consider a cabling channel comprising:
• optical fiber conforming to OS2 of ISO/IEC 11801-1;
• a total length including equipment cords of 500 m;
• two panel connections in accordance with ISO/IEC 11801-1;
• two optical fiber splices in accordance with ISO/IEC 11801-1;
• equipment cords terminated with connectors in accordance with ISO/IEC 11801-1.
The channel limit at 1 310 nm would be: (0,5 × 0,4 dB) + (2 × 0,75 dB) + (2 × 0,3 dB) = 2,3 dB
The channel limit at 1 550 nm would be: (0,5 × 0,4 dB) + (2 × 0,75 dB) + (2 × 0,3 dB)= 2,3 dB
Example 3 - Multi-mode permanent link
Consider a permanent link comprising:
• optical fiber conforming to OM3 of ISO/IEC 11801-1;
• a total length of 100 m;
• two panel connections in accordance with ISO/IEC 11801-1.
Using the 1-jumper reference method, the limit would be as follows:
• at 850 nm: (0,1 × 3,5 dB) + (2 × 0,45 dB) = 1,25 dB;
• at 1 300 nm: (0,1 × 1,5 dB) + (2 × 0,45 dB) = 1,05 dB
Example 4 - Single-mode permanent link
Consider a permanent link comprising:
• optical fiber conforming to OS2 of ISO/IEC 11801-1;
• a total length of 500 m;
• two panel connections in accordance with ISO/IEC 11801-1;
• two optical fiber splices in accordance with ISO/IEC 11801-1.
Using the enhanced 3-jumper or 1-jumper reference method, the limit would be as follows:
• at 1 310 nm: (0,5 × 0,4 dB) + (2 × 0,7 dB) + (2 × 0,3 dB) = 2,2 dB;
• at 1 550 nm: (0,5 × 0,4 dB) +(2 × 0,7 dB) + (2 × 0,3 dB) = 2,2 dB