ISO/IEC 14763-3:2024: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 25: Line 25:
| 1.0
| 1.0
|1.0
|1.0
|5000
|10000
|-
|-
|OS2
|OS2
Line 35: Line 35:
|0.4
|0.4
|0.4
|0.4
|5000
|10000
|-
|-
|OM1, OM2, OM3, OM4, OM5
|OM1, OM2, OM3, OM4,
|0.75
|0.75
|0.45
|0.45
|0.3
|0.3
|3.5
|3.5
|1.5
| -
| -
|2000
|-
|OM5
|0.75
|0.45
|0.3
|3.0
|1.5
|1.5
| -
| -

Latest revision as of 07:04, 13 February 2025

Introduction

This is an extract of the most recent publication of the standard ISO/IEC 14763-3 in 2024. Information technology, implementation and operation of customer premises cabling, part 3, testing of optical fiber cabling. Please purchase the full document at ISO Store.

Solution

Table

Cable type* Adapter loss embedded (dB) Adapter loss first and last (dB) Splice loss Fiber loss @ 850nm (dB/km) Fiber loss @ 1300nm (dB/km) Fiber loss @ 1310nm (dB/km) Fiber loss @ 1550nm (dB/km) Length (m)
OS1/OS1a 0.75 0.7 0.3 - - 1.0 1.0 10000
OS2 0.75 0.7 0.3 - - 0.4 0.4 10000
OM1, OM2, OM3, OM4, 0.75 0.45 0.3 3.5 1.5 - - 2000
OM5 0.75 0.45 0.3 3.0 1.5 - - 2000

Examples

Example 1 - Multi-mode channel

Consider a cabling channel comprising:

• optical fiber conforming to OM4 of ISO/IEC 11801-1;

• a total length including equipment cords of 100 m;

• two panel connections in accordance with ISO/IEC 11801-1;

• equipment cords terminated with connectors in accordance with ISO/IEC 11801-1.

The channel limit at 850 nm would be: (0,1 × 3,5 dB) + (2 × 0,75 dB) = 1,85 dB

The channel limit at 1 300 nm would be: (0,1 × 1,5 dB) + (2 × 0,75 dB) = 1,65 dB

Example 2 - Single-mode channel

Consider a cabling channel comprising:

• optical fiber conforming to OS2 of ISO/IEC 11801-1;

• a total length including equipment cords of 500 m;

• two panel connections in accordance with ISO/IEC 11801-1;

• two optical fiber splices in accordance with ISO/IEC 11801-1;

• equipment cords terminated with connectors in accordance with ISO/IEC 11801-1.

The channel limit at 1 310 nm would be: (0,5 × 0,4 dB) + (2 × 0,75 dB) + (2 × 0,3 dB) = 2,3 dB

The channel limit at 1 550 nm would be: (0,5 × 0,4 dB) + (2 × 0,75 dB) + (2 × 0,3 dB)= 2,3 dB

Example 3 - Multi-mode permanent link

Consider a permanent link comprising:

• optical fiber conforming to OM3 of ISO/IEC 11801-1;

• a total length of 100 m;

• two panel connections in accordance with ISO/IEC 11801-1.

Using the 1-jumper reference method, the limit would be as follows:

• at 850 nm: (0,1 × 3,5 dB) + (2 × 0,45 dB) = 1,25 dB;

• at 1 300 nm: (0,1 × 1,5 dB) + (2 × 0,45 dB) = 1,05 dB

Example 4 - Single-mode permanent link

Consider a permanent link comprising:

• optical fiber conforming to OS2 of ISO/IEC 11801-1;

• a total length of 500 m;

• two panel connections in accordance with ISO/IEC 11801-1;

• two optical fiber splices in accordance with ISO/IEC 11801-1.

Using the enhanced 3-jumper or 1-jumper reference method, the limit would be as follows:

• at 1 310 nm: (0,5 × 0,4 dB) + (2 × 0,7 dB) + (2 × 0,3 dB) = 2,2 dB;

• at 1 550 nm: (0,5 × 0,4 dB) +(2 × 0,7 dB) + (2 × 0,3 dB) = 2,2 dB


*OS1, OM1 and OM2 are no longer to be used with new installations.