Revision as of 17:52, 3 September 2017

Introduction

Solution

 

Enabling secure communication between the ASE, PAC and TruView Central should be the same for all ASEs running firmware version 6.9 or higher. This procedure has been tested on ASE Series 1900 and Series 400.

Connect to the ASE

Telnet (tcp/23) Serial port (8N1, 19200)

Login to ASE 

Default credentials admin/visual

Before secure communication can be configured, unsecure IP communication (Telnet) must be established between the ASE and TruView Central. If this is not allowed by your company's security policy, these steps must be completed in the lab.

Check for security command and enter the settings as follows. You can add Host Address Security at a later stage. Be prepared to set a passcode. For security reasons, this should be different from the login password.

Parameter Value Remarks
Security Level Partial -
SSL TCP Port 2359 -
Change Management Passcode Y -
Enter Management Passcode <passcode> -
Change Host Address Security Table None Can be added later

Check the setttings and notice that the field Managent Passcode reads None. This is expected.

CRT-DEV-ASE007> sh sec

    Security Level:          Partial
    SSL TCP Port :           2359
    Management passcode:     None
    Pending passcode:        Ready
    Remote Console Protocol: SSH
    Host Address Security:   Disabled

    Host Address Security Table: EMPTY

Check the setttings and notice that the field Managent Passcode reads None. This is expected.

 

Locate and run IPTool located on TruView Central. IPTool is an unsupported utility for use by Fluke Networks technical support.

C:\Program Files (x86)\Fluke Networks\Visual Performance Manager Server\iptool.exe

From IPTool fetch any command for appflows or voip data by entering the passcode you have chosen in the previous step.

Click TFTP GET in the top left corner of the windows and enter the ASE's settings per this example.

<IPToolTFTPGet>

Click Go. The results you get are irellevant at this time. The procedure enables secure communication on the ASE.