CertiFiber Pro test reference cords: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
(Created page with " === Introduction === Loss and length testing in accordance with ISO/IEC 14763-3 requires the use of test reference cords.  Furthermore, test reference cords and the 1-...")
 
No edit summary
Line 2: Line 2:
=== Introduction ===
=== Introduction ===


Loss and length testing in accordance with ISO/IEC 14763-3 requires the use of test reference cords. 
Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords. 


Furthermore, test reference cords and the 1-jumper reference should be used under all circumances because it is the only way to ensure maximum test accuracy.
Furthermore, test reference cords and the 1-jumper reference should be used to ensure maximum test accuracy.


The Fluke Network CetriFiber Pro optical loss test set (OLTS) comes standard with all accesories needed to test LC-to-LC fiber optic links. 
The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes standard with all accesories needed to test LC-to-LC fiber optic links.


 
 
Line 12: Line 12:
=== Solution ===
=== Solution ===


In those cases where you need to test SC-to-SC or SC-to-C filer optic links, you need to acquire the accessories listed below.
In those cases where you need to test not only LC-to-LC but also SC-to-SC and SC-to-LC fiber optic links, you need to acquire the accessories listed below.


Further information on how to use these accessories can be found in the Certiffied Cable Test Technican program.
Further information on how to use these accessories can be found in the Certiffied Cable Test Technican program.
{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;"
|-
| Product
| Model
| Description
| Included with tester
| Required for testing (LC-to-LC and SC-to-SC)
| Required for testing (LC-to-LC, SC-to-SC and LC-to-SC)
|-
| 2635936
| NFA-LC
| LC Test Adapter Set of Two
| 1
| 1
|
|-
| 4320193
| MRC-50-EFC-SCLC
| Multimode EF TRC 2m 50µ (2xLC/LC, 2xSC/LC)
| 1
| 1
|
|-
| 4335564
| SRC-9-SCLC-KIT
| Singlemode TRC Kit 2m (2xLC/LC, 2xSC/LC)
| 1
| 1
|
|-
|  
|  
|  
|  
|  
|  
|}


 
 

Revision as of 16:34, 14 September 2017

Introduction

Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords. 

Furthermore, test reference cords and the 1-jumper reference should be used to ensure maximum test accuracy.

The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes standard with all accesories needed to test LC-to-LC fiber optic links.

 

Solution

In those cases where you need to test not only LC-to-LC but also SC-to-SC and SC-to-LC fiber optic links, you need to acquire the accessories listed below.

Further information on how to use these accessories can be found in the Certiffied Cable Test Technican program.

Product Model Description Included with tester Required for testing (LC-to-LC and SC-to-SC) Required for testing (LC-to-LC, SC-to-SC and LC-to-SC)
2635936 NFA-LC LC Test Adapter Set of Two 1 1
4320193 MRC-50-EFC-SCLC Multimode EF TRC 2m 50µ (2xLC/LC, 2xSC/LC) 1 1
4335564 SRC-9-SCLC-KIT Singlemode TRC Kit 2m (2xLC/LC, 2xSC/LC) 1 1