CertiFiber Pro test reference cords: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 75: | Line 75: | ||
Please remember that TRC are consumables and subject to deterioration in case they need replacement. | Please remember that TRC are consumables and subject to deterioration in case they need replacement. | ||
| | ||
Line 118: | Line 80: | ||
| | ||
| === === | ||
| | ||
| |
Revision as of 17:23, 14 September 2017
Introduction
Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords.
Furthermore, test reference cords and the 1-jumper reference should be used to ensure maximum test accuracy.
The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes standard with all accesories needed to test LC-to-LC fiber optic links.
Solution
Accessories
In those cases where you need to test not only LC-to-LC but also SC-to-SC and SC-to-LC fiber optic links, you need to acquire the accessories listed below.
Further information on how to use these accessories can be found in the Certiffied Cable Test Technican program.
Product | Model | Description | Included with tester | Required for testing (LC-to-LC and SC-to-SC) | Required for testing (LC-to-LC, SC-to-SC and LC-to-SC) |
2635934 |
NFA-LC | Set of LC Test Adapters (2) | 1 | 1 | 1 |
4320262 | MRC-50EFC-SCLCKIT | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm LC Fibers | 1 | 1 | 2 |
4335564 | SRC-9-SCLC-KIT | Singlemode Test Reference Cord (TRC) Kit, 2m, (2) SC/LC, (2) LC/LC | 1 | 1 | 2 |
2635929 |
NFA-SC | SC Test Adapter Set of Two | 0 | 1 | 1 |
4322705 | MRC-50EFC-SCSCKIT | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm SC Fibers | 0 | 1 | 1 |
4334464 | SRC-9-SCSC-KIT | Singlemode Test Reference Cord (TRC) Kit, 2m, (4) SC/SC | 0 | 1 | 1 |
Please remember that TRC are consumables and subject to deterioration in case they need replacement.