Revision as of 15:14, 15 September 2017
Introduction
The limits stipulated in ISO1801 are not longer usable to evaluate the quality of a recently installed fiber optic link. They are too relaxed.
These values are not applicable when testing links containing MPO connectors.
Solution
We recommend the use of this custom limit for length/loss testing. More context will be given during the Certified Cabling Test Training module VERSIVFO.
Parameter | Default value | Recommended value |
Length (m) | 2000,0 | 2000,0 |
Connection Loss (dB) | 0,75 | 0,30 |
Splice Loss (dB) | 0,30 | 0,15 |
Loss/km @ 850nm (dB/km) | 3,00 | 3,00 |
Loss/km @ 1300nm (dB/km) | 1,50 | 1,50 |
Loss/km @ 1310nm (dB/km) | 1,00 | 1,00 |
Loss/km @ 1550nm (dB/km) | 1,00 | 1,00 |