We recommend the use of this custom limit for length/loss. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit. For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More | We recommend the use of this custom limit for length/loss. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit. For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More information is available during the Certified Cabling Test Training module VERSIVFO. | ||
{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;" | {| border="1" cellpadding="1" cellspacing="1" style="width: 500px;" |
Revision as of 05:23, 16 September 2017
Introduction
It is our opinion that the lenght/loss limit specified in ISO/IEC 18011:2010 is not longer adequate to evaluate the quality of a recently installed fiber optic link; they are too relaxed.
Solution
We recommend the use of this custom limit for length/loss. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit. For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More information is available during the Certified Cabling Test Training module VERSIVFO.
Parameter | Default value | Recommended value |
Length (m) | 2000,0 | 2000,0 |
Connection Loss (dB) | 0,75 | 0,30 |
Splice Loss (dB) | 0,30 | 0,15 |
Loss/km @ 850nm (dB/km) | 3,00 | 3,00 |
Loss/km @ 1300nm (dB/km) | 1,50 | 1,50 |
Loss/km @ 1310nm (dB/km) | 1,00 | 1,00 |
Loss/km @ 1550nm (dB/km) | 1,00 | 1,00 |