CertiFiber Pro test reference cords: Difference between revisions
No edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
== Introduction == | == Introduction == | ||
Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords. Test reference cords have a much lower | Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords. Test reference cords have a much lower Insertion Loss (IL) in comparison to off the shelf patch cords. Furthermore, test reference cords and the 1-jumper reference should be used to ensure maximum test accuracy. The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes with all accesories needed to test LC-to-LC fiber optic links. | ||
| |
Revision as of 11:03, 17 September 2017
Introduction
Loss and length testing in accordance to ISO/IEC 14763-3 requires the use of test reference cords. Test reference cords have a much lower Insertion Loss (IL) in comparison to off the shelf patch cords. Furthermore, test reference cords and the 1-jumper reference should be used to ensure maximum test accuracy. The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes with all accesories needed to test LC-to-LC fiber optic links.
Solution
Accessories
In those cases where you need to test not only LC-to-LC but also SC-to-SC and SC-to-LC fiber optic links, you need to purchase the accessories listed below.
Further information on how to use these accessories will be explained during our Certified Cable Test Training VERSIVFO module.
Product | Model | Description | Included with tester | Required for testing (LC-to-LC and SC-to-SC) | Required for testing (LC-to-LC, SC-to-SC and LC-to-SC) |
2635934 |
NFA-LC | Set of LC Test Adapters (2) | 1 | 1 | 1 |
4320262 | MRC-50EFC-SCLCKIT (*) | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm LC Fibers | 1 | 1 | 2 |
4335564 | SRC-9-SCLC-KIT (*) | Singlemode Test Reference Cord (TRC) Kit, 2m, (2) SC/LC, (2) LC/LC | 1 | 1 | 2 |
2635929 |
NFA-SC | SC Test Adapter Set of Two | 0 | 1 | 1 |
4322705 | MRC-50EFC-SCSCKIT (*) | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm SC Fibers | 0 | 1 | 1 |
4334464 | SRC-9-SCSC-KIT (*) | Singlemode Test Reference Cord (TRC) Kit, 2m, (4) SC/SC | 0 | 1 | 1 |
(*) This is a consumable. In accordance to ISO/IEC 61300-2-2, the mechanical endurance (durability) of the connecting hardware shall be ≥500 cycles:
- LC typical 500 to 1000 cycles
- SC typical 2000 to 5000 cycles