Introduction

To minimize the risk of data loss, it is recommended that all services are stopped before restarting or shutting down the machine.

 

Solution

 

 

nGeniusONE server

  • Connect to the management interface using an SSH client of your choice
  • Login as root (for default credentials read default credentials)
  • Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
  • Stop all running processes
# ./stop
  • Check if all processes are stopped; the only process left running should be Xvfb
# ./PS
  • Shutdown (h) or reboot (r) the machine
# shutdown -h now

 

Infinistream and vStream

  • Connect to the management interface using an SSH client of your choice
  • Login as root (for default credentials read default credentials)
  • Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
  • Execute the stop script
# ./stopall
  • Check if all processes are stopped, these should be no processes left running
# ./PS
  • Shutdown (h) or reboot (r) the machine
# shutdown -h now

 

vScout

  • Connect to the host using an SSH client of your choice
  • Login as root (for default credentials read default credentials)
  • Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
  • Stop the vScout service
# service vscoutd stop
  • Shutdown (h) or reboot (r) the guest machine
# shutdown -h now