Adjusting fan speed: Difference between revisions
(Created page with " == Introduction == Starting with Dell's PowerEdge 12th generation servers, Dell has introduced a fan speed offset setting that enables fan speed to be increased and decrease...") |
No edit summary |
||
Line 6: | Line 6: | ||
Netscout has decided to apply a Termal Profile for maximum performance which leads to maximum fan speed and the corresponding sound level of nearly 81dBA. | Netscout has decided to apply a Termal Profile for maximum performance which leads to maximum fan speed and the corresponding sound level of nearly 81dBA. | ||
| |||
== Solution == | == Solution == | ||
Line 20: | Line 20: | ||
| | ||
=== Setting the fan speed === | |||
The thermal profile and fan speed can be configured via iDRAC Settings during boot or via the iDRAC Web UI. | |||
iDRAC Settings: | |||
*At boot, press '''<F2>''' | |||
*Select '''iDRAC Settings''', then '''Thermal '''all way down the list | |||
iDRAC Web UI: | |||
*Login | |||
*In the laft panel expand '''Overview''' > '''Hardware''' | |||
*Select '''Fans''' in the left and '''Setup''' in the right panel | |||
We recommend the following settings: | |||
Termal Profile: Default Thermal Profile | |||
Fan Speed Offset: High (+55%) | |||
| |||
| |||
| | ||
| |
Revision as of 18:20, 20 July 2018
Introduction
Starting with Dell's PowerEdge 12th generation servers, Dell has introduced a fan speed offset setting that enables fan speed to be increased and decreased. 3rd party add-in cards - such as Netscout's "Sniddely" analysis card found on TruView Packet (TVP) and TruView Appliance (TVA) - need increased fan speed to provide additional cooling.
Netscout has decided to apply a Termal Profile for maximum performance which leads to maximum fan speed and the corresponding sound level of nearly 81dBA.
Solution
DO NOT set the Fan Speed Offset too low. The Sniddely analysis card needs additional cooling. Setting the Fan Speed Offset too low may compromise the hardware and void warranty. As guidance, the tempertature of the CPU should never rise above 55°C |
Dell changed the iDRAC configuration menu ever so slightly with every new release of the firmware. The way to configure this setting may not be exactly the same as stated below. |
Setting the fan speed
The thermal profile and fan speed can be configured via iDRAC Settings during boot or via the iDRAC Web UI.
iDRAC Settings:
- At boot, press <F2>
- Select iDRAC Settings, then Thermal all way down the list
iDRAC Web UI:
- Login
- In the laft panel expand Overview > Hardware
- Select Fans in the left and Setup in the right panel
We recommend the following settings:
Termal Profile: Default Thermal Profile
Fan Speed Offset: High (+55%)