OptiFiber Pro custom test limit: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 18: Line 18:
{| style="width: 800px" cellspacing="1" cellpadding="1" border="1"
{| style="width: 800px" cellspacing="1" cellpadding="1" border="1"
|-
|-
! scope="col" style="width: 332px" | Parameter
! scope="col" style="width: 332px" | Parameter (m)
! scope="col" style="width: 455px" | Recommended value
! scope="col" style="width: 455px" | Recommended value
|-
|-
| style="width: 332px" | Length (m)
| style="width: 332px" | Length
| style="width: 455px;  text-align: right" | N/A
| style="width: 455px;  text-align: right" | N/A
|}
|}
Line 39: Line 39:
! scope="col" | 1625nm
! scope="col" | 1625nm
|-
|-
| Overall Loss (Max)
| Overall Loss (Max) (dB)
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
Line 47: Line 47:
| style="text-align: right" | N/A
| style="text-align: right" | N/A
|-
|-
| Overall Loss (Min)
| Overall Loss (Min) (dB)
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
Line 55: Line 55:
| style="text-align: right" | N/A
| style="text-align: right" | N/A
|-
|-
| Optical Return Loss
| Optical Return Loss (dB)
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
Line 63: Line 63:
| style="text-align: right" | N/A
| style="text-align: right" | N/A
|-
|-
| Segment Attenuation Coefficient (Max)
| Segment Attenuation Coefficient (Max) (dB/km)
| style="text-align: right" | 3.0
| style="text-align: right" | 3.0
| style="text-align: right" | 1.5
| style="text-align: right" | 1.5
Line 71: Line 71:
| style="text-align: right" | 1.0
| style="text-align: right" | 1.0
|-
|-
| Segment Attenuation Coefficient (Min)
| Segment Attenuation Coefficient (Min) (dB/km)
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
| style="text-align: right" | N/A
Line 86: Line 86:
{| style="width: 800px" cellspacing="1" cellpadding="1" border="1"
{| style="width: 800px" cellspacing="1" cellpadding="1" border="1"
|-
|-
! scope="col" | Parameter
! scope="col" | Parameter (dB)
! scope="col" | 850nm
! scope="col" | 850nm
! scope="col" | 1300nm
! scope="col" | 1300nm
Line 149: Line 149:
{| style="width: 800px" cellspacing="1" cellpadding="1" border="1"
{| style="width: 800px" cellspacing="1" cellpadding="1" border="1"
|-
|-
! scope="col" | Parameter
! scope="col" | Parameter (dB)
! scope="col" | 850nm*
! scope="col" | 850nm*
! scope="col" | 1300nm*
! scope="col" | 1300nm*

Revision as of 18:10, 12 January 2019

Introduction

Limits specified by ISO/IEC11801:2017 and ISO/IEC14763-3:2014 (Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling) are no longer adequate to evaluate the quality of recently installed fiber optic infrastructure.

This article was recently updated for firmware version 6.0 (January 2019).

 

Solution

Use these recommended values to create one custom limit for testing PC/UPC terminated links and a second custom limit for testing APC terminated links.

 

Maximum length for PC, UPC and APC terminated links

Parameter (m) Recommended value
Length N/A

 

General Settings for PC, UPC and APC terminated links

Parameter 850nm 1300nm 1310nm 1490nm 1550nm 1625nm
Overall Loss (Max) (dB) N/A N/A N/A N/A N/A N/A
Overall Loss (Min) (dB) N/A N/A N/A N/A N/A N/A
Optical Return Loss (dB) N/A N/A N/A N/A N/A N/A
Segment Attenuation Coefficient (Max) (dB/km) 3.0 1.5 1.0 1.0 1.0 1.0
Segment Attenuation Coefficient (Min) (dB/km) N/A N/A N/A N/A N/A N/A

 

Event Settings for PC and UPC terminated links

Parameter (dB) 850nm 1300nm 1310nm 1490nm 1550nm 1625nm
Connector Loss (Max) 0.30 0.30 0.30 0.30 0.30 0.30
Connector Loss (Min) N/A N/A N/A N/A N/A N/A
Splice Loss (Max) 0.15 0.15 0.15 0.15 0.15 0.15
Splice Loss (Min) N/A N/A N/A N/A N/A N/A
Reflectance (Max) -35.00 -35.00 -45.00 -45.00 -45.00 -45.00
Reflectance (Min) N/A N/A N/A N/A N/A N/A

 

Event Settings for APC terminated links

Parameter (dB) 850nm* 1300nm* 1310nm 1490nm 1550nm 1625nm
Connector Loss (Max)     0.30 0.30 0.30 0.30
Connector Loss (Min)     N/A N/A N/A N/A
Splice Loss (Max)     0.30 0.30 0.30 0.30
Splice Loss (Min)     N/A N/A N/A N/A
Reflectance (Max)     -65.00 -65.00 -65.00 -65.00
Reflectance (Min)     N/A N/A N/A N/A

(*) APC style connectors aren't used on multi-mode fiber links. You may decide to keep the default values for multi-mode wavelengths.