Revision as of 11:58, 9 March 2019
Introduction
Many fiber optic technicians are unfamiliar working with logarithmic units like decibel (dB).
This table allows you to get a grasp on the relationship between loss on a logartimic scale (dB) and optical power reduction on a liniar scale (%).
Solution
Attenuation | Optical Power Reduction |
---|---|
0 dB | 0% |
1 dB | 21% |
2 dB | 37% |
3 dB | 50% |
4 dB | 60% |
5 dB | 68% |
6 dB | 75% |
7 dB | 80% |
10 dB | 90% |
13 dB | 95% |
15 dB | 96.8% |