=== Network connections (appliance rear view) ===
=== Network connections (appliance rear view) ===


This picture shows the minimal set of ports that must be connected in order to operate normally.
This picture shows the minimal set of ports that must be connected in order to operate normally.  More connections ma required 


Port 1: MANagement port: this port must be connected to a local switchport.
<u>All models:</u>


Port 2: not connected.
LAN 1: MANagement port: this port must be connected to a local switchport.


Port 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*.
LAN 2: not connected.


Port 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*.
LAN 5: (SFP not present), not connected.


Port 5: (SFP not present), not connected.
LAN 6: (SFP not present), not connected.


Port 6: (SFP not present), not connected.
<u>SPAN model:</u>
 
LAN 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*.
 
LAN 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*.
 
<u>TAP model (inline):</u>
 
Install&nbsp;the appliance between the WAN Access Device&nbsp;and the local switch.&nbsp; Connect LAN3 to the WAN access device and LAN4 to the local switch.&nbsp; The applicance does not provide PoE.


(*) See configuration examples for Alcatel Lucent
(*) See configuration examples for Alcatel Lucent

Revision as of 14:14, 11 August 2020

WIP.jpg
WIP.jpg

Network connections (appliance rear view)

This picture shows the minimal set of ports that must be connected in order to operate normally.  More connections ma required 

All models:

LAN 1: MANagement port: this port must be connected to a local switchport.

LAN 2: not connected.

LAN 5: (SFP not present), not connected.

LAN 6: (SFP not present), not connected.

SPAN model:

LAN 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*.

LAN 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*.

TAP model (inline):

Install the appliance between the WAN Access Device and the local switch.  Connect LAN3 to the WAN access device and LAN4 to the local switch.  The applicance does not provide PoE.

(*) See configuration examples for Alcatel Lucent

(*) See configuration examples for Cisco

 

 

System dimensions

Width: 220mm (without mounting brackets) 430mm (with 19" mounting brachets)

Hight: 44mm

Depth: 105mm

 

Weight

kg (without mounting brackets)

 

PSU specifications

PSU (Power): External power supply (IEC320 C14 connector)

Maximum heat dissipation: 

Frequency: 50Hz - 60Hz

Voltage: 100V - 240V AC

Maximum current: 1.5A

Power based on observation: 

 

Operating parameters

Temperature: 0°C - 40°C

Humidity: 10% - 80% RH non-condensing

Vibration: 0.5Grms / 5Hz ~ 500Hz 

Shock: 10G