NSE-12 and NSE-22 quick start guide: Difference between revisions
No edit summary |
No edit summary |
||
| Line 19: | Line 19: | ||
| | ||
==== The appliance is accessible through ssh using a terminal emulator program and via a serial console located on the back of the appliance. It ships with two local user accounts, ''Administrator'' and ''comcert''. User ''Administrator'' has been created for the end-user to safely shut down and reboot the appliance. User ''comcert'' is reserved for COMCERT Support (C-TAC). ==== | |||
==== Using the network and ssh: ==== | ==== Using the network and ssh: ==== | ||
==== To connect to NSE from another computer running a terminal session, run the following command: ==== | |||
<pre>ssh -l Administrator <IPaddressPMA></pre> | <pre>ssh -l Administrator <IPaddressPMA></pre> | ||
Using the serial console: | |||
Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600 8N1. | Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600 8N1. | ||
Revision as of 14:40, 12 August 2020
Introduction
Network Service Element come in two varieties: SPAN and TAP.
The SPAN model has two independent monitor interfaces labeled LAN 3 and LAN 4. In a typical configuration, both ports will be connected to two SPAN output ports: one port representing all packets from the network to the site and the other port representing all packets in the opposite direction. The NSE offers great WAN visibility, including a more precise traffic measurements method than possible with flow based analysis or snmp. Other applications of NSE are possible, for example the monitoring of server bound traffic in a relatively small remote datacenter.
The fail-safe TAP model has been designed to be installed inline between the CPE and the local switch. No specific configuration of those devices is required.
Solution
Connect to the appliance
| We recommend using MobaXterm to access the appliance. Download MobaXterm at: http://mobaxterm.mobatek.net/download.html |
The appliance is accessible through ssh using a terminal emulator program and via a serial console located on the back of the appliance. It ships with two local user accounts, Administrator and comcert. User Administrator has been created for the end-user to safely shut down and reboot the appliance. User comcert is reserved for COMCERT Support (C-TAC).
Using the network and ssh:
To connect to NSE from another computer running a terminal session, run the following command:
ssh -l Administrator <IPaddressPMA>
Using the serial console:
Use a serial cable to connect to the RS-232/RJ45 serial port on the backside of the NSE. Set the serial port on your computer to match the settings of the appliance: 9600 8N1.
Shutdown and reboot the appliance
| All applications must be brought-down properly before shutting-down or rebooting the appliance. Failure to do so may result in loss of recorded data. |
Connect to NSE and login as Administrator.
Once authenticated, run one of the following commands:
To shut-down the appliance:
$ sudo systemctl halt
To reboot the appliance:
$ sudo systemctl reboot
In case and only in case the above commands fail (risk of data loss):
To power-off the appliance (equivalent of removing the power source).
$ sudo systemctl poweroff