CertiFiber Pro test reference cords: Difference between revisions
No edit summary |
No edit summary |
||
| Line 20: | Line 20: | ||
| style="width: 300px;" | Description | | style="width: 300px;" | Description | ||
| style="width: 124px;" | Included with tester | | style="width: 124px;" | Included with tester | ||
| style="width: 244px;" | | | style="width: 244px;" | Needed for testing (LC-to-LC and SC-to-SC) | ||
| style="width: 241px;" | | | style="width: 241px;" | Needed for testing (LC-to-LC, SC-to-SC and LC-to-SC) | ||
|- | |- | ||
| style="width: 61px;" | | | style="width: 61px;" | | ||
Revision as of 11:25, 31 January 2021
Introduction
Loss/length testing in accordance to ISO/IEC 14763-3:2014 requires the use of Test Reference Cords (TRC). TRC have less Insertion Loss (IL) in comparison to off the shelf patch cords. Furthermore, TRC and the 1-jumper reference should be used to ensure maximum test accuracy. The Fluke Network CertiFiber Pro optical loss test set (OLTS) comes with TRC and adapters required to properly test LC-to-LC fiber optic links.
Solution
Fluke Networks Accessories
In those cases where you need to test not only LC-to-LC but also SC-to-SC or SC-to-LC fiber optic links, you need to purchase the accessories listed below.
Further information on how to use these accessories will be explained during the Certified Cable Test Training VERSIVFO module.
| Product | Model | Description | Included with tester | Needed for testing (LC-to-LC and SC-to-SC) | Needed for testing (LC-to-LC, SC-to-SC and LC-to-SC) |
|
2635934 |
NFA-LC | Set of LC Test Adapters (2) | 1 | 1 | 1 |
| 4320262 | MRC-50EFC-SCLCKIT (*) | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm LC Fibers | 1 | 1 | 2 |
| 4335564 | SRC-9-SCLC-KIT (*) | Singlemode Test Reference Cord (TRC) Kit, 2m, (2) SC/LC, (2) LC/LC | 1 | 1 | 2 |
|
2635929 |
NFA-SC | SC Test Adapter Set of Two | 0 | 1 | 1 |
| 4322705 | MRC-50EFC-SCSCKIT (*) | Multimode Encircled Flux (EF) Test Reference Cord (TRC) kit for testing 50µm SC Fibers | 0 | 1 | 1 |
| 4334464 | SRC-9-SCSC-KIT (*) | Singlemode Test Reference Cord (TRC) Kit, 2m, (4) SC/SC | 0 | 1 | 1 |
(*) This is a consumable. In accordance to ISO/IEC 61300-2-2, the mechanical endurance (durability) of the connecting hardware shall be ≥500 cycles:
- LC typical 500 to 1000 cycles
- SC typical 2000 to 5000 cycles