*Name contains IEC or ISO  
*Name contains IEC or ISO  
*International standard, valid around the world  
*International standard, valid around the world  
*Component performance is called a "category"  
*Component performance is called a "category"  
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2  
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2  
 
*Installed link performance is called a "class"  
 
*Installed link performance is called a "class"  
**Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II  
**Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II  


Line 18: Line 16:
 
 


TIA
=== TIA ===


*Name contains TIA or ANSI/EIA/TIA  
*Name contains TIA or ANSI/EIA/TIA  
*National standard, valid in the United States of Amerika  
*National standard, valid in the United States of Amerika  
*Component performance is called a "category"  
*Component performance is called a "category"  
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8  
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8  
*Installed link performance is also called a "category"  
*Installed link performance is also called a "category"  
**Examples are Category 5e,Category 6,Category 6A, Category 8  
**Examples are Category 5e,Category 6,Category 6A, Category 8  
**Indeed, there is no such thing as a Category 7 or Category 7A link
**Indeed, there is no such thing as a Category 7 or Category 7A link
 
 

Revision as of 12:57, 11 September 2023

Popular Standards and Limits

ISO/IEC

  • Name contains IEC or ISO
  • International standard, valid around the world
  • Component performance is called a "category"
    • Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2
  • Installed link performance is called a "class"
    • Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II


ISO/IEC standards often form the basis of regional and national standards, including the European CENELEC standards

 

TIA

  • Name contains TIA or ANSI/EIA/TIA
  • National standard, valid in the United States of Amerika
  • Component performance is called a "category"
    • Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8
  • Installed link performance is also called a "category"
    • Examples are Category 5e,Category 6,Category 6A, Category 8
    • Indeed, there is no such thing as a Category 7 or Category 7A link