== Popular Standards and Limits ==
== Popular Cabling Standards and Limits ==


=== ISO/IEC ===
=== ISO/IEC ===
Line 8: Line 8:
*Component performance is called a "category"  
*Component performance is called a "category"  
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2  
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2  


*Installed link performance is called a "class"  
*Installed link performance is called a "class"  
Line 14: Line 13:




ISO/IEC standards often form the basis of regional and national standards, including the European CENELEC standards
ISO/IEC standards often form the basis of regional and national standards, including the CENELEC standards


 
 
Line 24: Line 23:
*Component performance is called a "category"  
*Component performance is called a "category"  
**Examples are Category 5e, Category 6, Category 6A, Category 7, Category 7A, Category 8  
**Examples are Category 5e, Category 6, Category 6A, Category 7, Category 7A, Category 8  


*Installed link performance is also called a "category"  
*Installed link performance is also called a "category"  
Line 33: Line 31:


 
 
=== CENELEC ===
*Name contains EN
*Regional standard, valid in the European Union
*Based on a pre-existing ISO/IEC standard 
*Component performance is called a "category"
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2
*Installed link performance is called a "class"
**Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II
These standards must be ratified and converted to a national standard by each Member State
 
=== NEN - NBN - ILNAS  ===
*Name contains NEN-, NBN, ILNAS-
*National standard, valid in a member state, respectively Netherlands, Belgium and G.D. Luxemburg
*Based on a pre-existing EN standard 
*Component performance is called a "category"
**Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2
*Installed link performance is called a "class"
**Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II
These standards are copy/paste from the EN standard.
 
=== IEEE ===
IEEE published application or network standards.
These are NOT cabling standards and therefore unsuited for installed link <u>certification</u>.&nbsp;
It is very unusual for an installer to <u>qualify</u> an installed link in accordance to an IEEE standard.&nbsp;&nbsp;

Revision as of 13:10, 11 September 2023

Popular Cabling Standards and Limits

ISO/IEC

  • Name contains IEC or ISO
  • International standard, valid around the world
  • Component performance is called a "category"
    • Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2
  • Installed link performance is called a "class"
    • Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II


ISO/IEC standards often form the basis of regional and national standards, including the CENELEC standards

 

TIA

  • Name contains TIA or ANSI/EIA/TIA
  • National standard, valid in the United States of Amerika
  • Component performance is called a "category"
    • Examples are Category 5e, Category 6, Category 6A, Category 7, Category 7A, Category 8
  • Installed link performance is also called a "category"
    • Examples are Category 5e, Category 6, Category 6A, Category 8


Indeed, there is no such thing as a Category 7 or Category 7A link

 

CENELEC

  • Name contains EN
  • Regional standard, valid in the European Union
  • Based on a pre-existing ISO/IEC standard 
  • Component performance is called a "category"
    • Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2
  • Installed link performance is called a "class"
    • Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II


These standards must be ratified and converted to a national standard by each Member State

 

NEN - NBN - ILNAS 

  • Name contains NEN-, NBN, ILNAS-
  • National standard, valid in a member state, respectively Netherlands, Belgium and G.D. Luxemburg
  • Based on a pre-existing EN standard 
  • Component performance is called a "category"
    • Examples are Category 5e,Category 6,Category 6A, Category 7, Category 7A, Category 8.1 and Category 8.2
  • Installed link performance is called a "class"
    • Examples are Class D, Class E, Class EA, Class F, Class FA, Class I, Class II


These standards are copy/paste from the EN standard.

 

IEEE

IEEE published application or network standards.

These are NOT cabling standards and therefore unsuited for installed link certification

It is very unusual for an installer to qualify an installed link in accordance to an IEEE standard.