Introduction

To prevent the server from sending duplicate Emails and alarms remove port 395 from the list of SNMP trap ports.

Solution

To reset the SNMP trap port list:

  • Log in to the Agent Configuration Utility and enter command-line mode
  • Enter option 11 (Enter Command-line mode) and press Enter
  • On the device command line, enter:
  • % set trap_port 162


  • Enter quit to exit command line mode and return to the menu.
  • Enter 12 to reset the device
  • Enter exit to log out of the Remote Console

Modify serverprivate.properties file by adding the following property:

  • globalsettings.netscout.trap.port=162