NSE-X2 connections and environmental specifications
Network connections (appliance rear view)
This picture shows the minimal set of ports that must be connected in order to operate normally.
Port 1: MANagement port: this port must be connected to a local switchport.
Port 2: not connected.
Port 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*.
Port 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*.
Port 5: (SFP not present), not connected.
Port 6: (SFP not present), not connected.
(*) See configuration examples for Alcatel Lucent
(*) See configuration examples for Cisco
System dimensions
Width: 220mm (without mounting brackets) 430mm (with 19" mounting brachets)
Hight: 44mm
Depth: 105mm
Weight
kg
PSU specifications
PSU (Power): 2x 1100W (IEC320 C14 connector)
Maximum heat dissipation: 4100BTU/h
Frequency: 50Hz
Voltage: 240V AC
Maximum current: 6.5A
Power based on observation: 500W maximum, 350W average (both PSU powered)