Shutdown nGeniusONE InfiniStream vScout and vStream
Introduction
To minimize the risk of data loss, it is recommended that all services are stopped before restarting or shutting down the machine.
Solution
| In case of vScout, double check if it's allowed to restart or shutdown the guest vScout is installed on. |
nGeniusONE server
- Connect to the management interface using an SSH client of your choice
- Login as root (for default credentials read default credentials)
- Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
- Stop all running processes
# ./stop
- Check if all processes are stopped; the only process left running should be Xvfb
# ./PS
- Shutdown (h) or reboot (r) the machine
# shutdown -h now
Infinistream and vStream
- Connect to the management interface using an SSH client of your choice
- Login as root (for default credentials read default credentials)
- Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
- Execute the stop script
# ./stopall
- Check if all processes are stopped, these should be no processes left running
# ./PS
- Shutdown (h) or reboot (r) the machine
# shutdown -h now
vScout
- Connect to the host using an SSH client of your choice
- Login as root (for default credentials read default credentials)
- Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
- Stop the vScout service
# service vscoutd stop
- Shutdown (h) or reboot (r) the guest machine
# shutdown -h now