Virtual machine from OVF properties

From wiki.comcert.com
Revision as of 10:45, 31 July 2019 by Bert (talk | contribs)
Jump to navigation Jump to search

Introduction

InfiniStream virtual appliances are build from OVF.

These are the properties of the vitual machines immediately after deployment.

Solution

nGenius Flow Collector Virtual Appliance (SKU: V-03300-32-PA)

Virtual Hardware Size
CPU 8
Memory 8 GB
Hard Disk 1 50 GB (Thick Provisioned)
Hard Disk 2 *
Network adapter 1 E1000

The size of the second hard disk that will serve as data store, is configurable during ovf deployment. 

The size of this hard disk depends on the number of flows per second received form the flow exporting devices and the number of days you want session details to remain available.

Use the table below for guidance.

Flow per second Retention Hard Disk 2 Size
5k 7 d 200 GB
20k 7 d 800 GB
50k 7 d 2 TB
5k 14 d 400 GB
20k 14 d 1600 GB
50k 14 d 4 TB

The second hard disk shall be Thick Provisioned.

 

vSTREAM STL (SKU: VSTREAM-0-008)

Virtual Hardware Size
CPU 2
Memory 2 GB
Hard Disk 1 32 GB (Thick Provisioned)
Hard Disk 2 *
Network adapter 1 VMXNET3

One to four additional interfaces for monitoring will be added after deployment.

The size of the second hard disk that will serve as data store, is configurable during ovf deployment.

The size of this hard disk depends on the expected traffic volume and how long you want packets to be available; it should not be less than 100GB.