Secure ASE Communication
Introduction
Solution
Enabling secure communication between the ASE, PAC and TruView Central should be the same for all ASEs running firmware version 6.9 or higher. This procedure has been tested on ASE Series 1900 and Series 400.
Connect to the ASE
Telnet (tcp/23) Serial port (8N1, 19200)
Login to ASE
Default credentials admin/visual
Check for security command and enter the settings as follows. You can add Host Address Security at a later stage. Be prepared to set a passcode. For security reasons, this should be different from the login password.
CRT-DEV-ASE007> sh sec Security Level: Partial SSL TCP Port : 2359 Management passcode: Set Pending passcode: Ready Remote Console Protocol: SSH Host Address Security: Disabled Host Address Security Table: EMPTY
Locate and run IPTool located on TruView Central. IPTool is an unsupported utility for use by Fluke Networks technical support.
C:\Program Files (x86)\Fluke Networks\Visual Performance Manager Server\iptool.exe
From iptool fetch any command for appflows or voip data by entering the passcode you have chosen in the previous step