OptiFiber Pro custom test limit

From wiki.comcert.com
Revision as of 05:10, 16 September 2017 by Bert (talk | contribs)
Jump to navigation Jump to search

Introduction

The limits stipulated in ISO1801 are not longer usable to evaluate the quality of a recently installed fiber optic link.  They are too relaxed. These values are not applicable when testing links containing MPO connectors.

 

Solution

We recommend the use of this custom limit for OTDR event evaluation. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit.  For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300 m and 2.6 dB (@ 850 nm). More context will be given during the Certified Cabling Test Training module VERSIVOTDR.

Maximum length

Parameter Default value Recommended value
Length (m) N/A N/A (*)

 

Limits for 850 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Reflectance (dB) -35,0 -35,0
Overall Loss (dB) N/A N/A (*)
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 3,00

 

Limits for 1300 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Reflectance (dB) -35,0 -35,0
Overall Loss (dB) N/A N/A (*)
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 1,50

 

Limits for 1310 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Reflectance (dB) -45,0 -45,0
Overall Loss (dB) N/A N/A (*)
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 1,00

 

Limits for 1550 nm

Parameter Default value Recommended value
Connector Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Reflectance (dB) -45,0 -45,0
Overall Loss (dB) N/A N/A (*)
Overall ORL (dB) N/A N/A
Segment Attenuation Coefficient (dB/km) N/A 1,00