CertiFiber Pro custom test limit

From wiki.comcert.com
Revision as of 13:07, 18 September 2017 by Bert (talk | contribs)
Jump to navigation Jump to search

Introduction

It is our opinion that the length/loss limits to be used with ISO/IEC14763-3:2014 (Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling) are no longer adequate to evaluate the quality of a recently installed fiber optic link; they are too relaxed.

 

Solution

We recommend this custom limit during length/loss testing. End-users could set Maximum Length and Maximum Overall Loss in accordance with the application limit.  For example, if the link is OM3 multimode fiber and the application is IEEE 10GBASE-SR, these values would be respectively 300m and 2,60dB (@ 850 nm). More information is available during the Certified Cabling Test Training module VERSIVFO.

Parameter Default value Recommended value
Length (m) 2000,0 2000,0
Connection Loss (dB) 0,75 0,30
Splice Loss (dB) 0,30 0,15
Loss/km @ 850nm (dB/km) 3,00 3,00
Loss/km @ 1300nm (dB/km) 1,50 1,50
Loss/km @ 1310nm (dB/km) 1,00 1,00
Loss/km @ 1550nm (dB/km) 1,00 1,00