Shutdown nGeniusONE InfiniStream vScout and vStream
Introduction
To minimize the risk of data loss, it is recommended that all services are stopped before restarting or shutting down the machine.
Solution
Double check if it's allowed to restart or shutdown the guest vScout is installed on. |
nGeniusONE server
- Connect to the management interface using an SSH client of your choice
- Login as root (for default credentials read default credentials)
- Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
- Stop all running processes
# ./stop
- Check if all processes are stopped; the only process left running should be Xvfb
# ./PS
- Shutdown (h) or reboot (r) the machine
# shutdown -h now
Infinistream and vStream
- Connect to the management interface using an SSH client of your choice
- Login as root (for default credentials read default credentials)
- Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
- Execute the stop script
# ./stopall
- Check if all processes are stopped, these should be no processes left running
# ./PS
- Shutdown (h) or reboot (r) the machine
# shutdown -h now
vScout
- Connect to the host using an SSH client of your choice
- Login as root (for default credentials read default credentials)
- Change to the folder /opt/Netscout/rtm/bin/
# cd /opt/Netscout/rtm/bin
- Stop the vScout service
# service vscoutd stop
- Shutdown (h) or reboot (r) the guest machine
# shutdown -h now