PMA-2XX Physical installation connections and environmental specifications

From wiki.comcert.com
Revision as of 16:30, 23 January 2019 by Bert (talk | contribs)
Jump to navigation Jump to search

Appliance rear view

This picture shows the minimal set of ports that must be connected.

 

PMA-222 Min Conn.png
PMA-222 Min Conn.png

 

Network connections

On the server's motherboard:

IP management interface (iDRAC): 1x 1000BASE-T

Management port (MGT): 2x 1000BASE-T and 2x 10GBASE-T. It is recommended to connect the first 1000BASE-T port. This is port "eth0".

Located on the ASI Accelerator NIC:

Monitor port (MON): 4x SFP+.

The SFP+ slots are empty and must be equipped with fiber optic transceivers. Copper transceivers are not supported. One or more of these ports must be connected to a SPAN or TAP.  The ports are numbered from right to left. The port on the right is named "if3" in nGeniusONE.

 

System dimensions

Width: 430.0mm (19 inch)

Hight: 86.8mm (2U)

Depth: 715.5mm

 

Weight

33.1kg

 

PSU specifications

PSU (Power): 2x 1100W (IEC320 C14 connector)

Heat dissipation: 4100BTU/h

Frequency: 50Hz

Voltage: 240V AC

Current: 6.5A

Server power consumption based on observation: 500W maximum, 400W average (both PSU powered)

 

Network connections

Located on the server's motherboard:

Out-of-band management and virtual console (iDRAC): 1x 1000BASE-T

Management (MGT): 2x 1000BASE-T and 2x 10GBASE-T. At least one of these ports must be connected to a switch port.

Located on the ASI Accelerator NIC:

Monitor (MON): 4x SFP+. These slots are empty and must be equipped with fiber optic transceivers. Copper transceivers are not supported. One or more of these ports must be connected to a SPAN or TAP.  Ports are numbered from right to left, starting at number 3 then 4, 5 and 6.