PMA-2XX Physical installation connections and environmental specifications
Network connections (appliance rear view)
This picture shows the minimal set of ports that must be connected.
Located on the server base:
IP management interface (iDRAC): 1x 1000BASE-T
Management port (MGT): 2x 1000BASE-T and 2x 10GBASE-T. It is recommended to connect the first 1000BASE-T port. This is port "eth0".
Located on the ASI Accelerator NIC:
Monitor port (MON): 4x SFP+.
The SFP+ slots are empty and must be equipped with fiber optic transceivers. Copper transceivers are not supported. One or more of these ports must be connected to a SPAN or TAP. The ports are numbered from right to left. The port on the right is named "if3" in nGeniusONE.
System dimensions
Width: 430.0mm (19 inch)
Hight: 86.8mm (2U)
Depth: 715.5mm
Weight
33.1kg
PSU specifications
PSU (Power): 2x 1100W (IEC320 C14 connector)
Heat dissipation: 4100BTU/h
Frequency: 50Hz
Voltage: 240V AC
Current: 6.5A
Server power consumption based on observation: 500W maximum, 400W average (both PSU powered)
Network connections
Located on the server's motherboard:
Out-of-band management and virtual console (iDRAC): 1x 1000BASE-T
Management (MGT): 2x 1000BASE-T and 2x 10GBASE-T. At least one of these ports must be connected to a switch port.
Located on the ASI Accelerator NIC:
Monitor (MON): 4x SFP+. These slots are empty and must be equipped with fiber optic transceivers. Copper transceivers are not supported. One or more of these ports must be connected to a SPAN or TAP. Ports are numbered from right to left, starting at number 3 then 4, 5 and 6.