NSE-X2 connections and environmental specifications

From wiki.comcert.com
Revision as of 13:58, 11 August 2020 by Bert (talk | contribs)
Jump to navigation Jump to search
WIP.jpg
WIP.jpg

Network connections (appliance rear view)

This picture shows the minimal set of ports that must be connected in order to operate normally.

Port 1: MANagement port: this port must be connected to a local switchport.

Port 2: not connected.

Port 3: MONitor port: this port must be connected to the SPAN representing the traffic FROM the network*.

Port 4: MONitor port: this port must be connected to the SPAN representing the traffic TO the network*.

Port 5: (SFP not present), not connected.

Port 6: (SFP not present), not connected.

(*) See configuration examples for Alcatel Lucent

(*) See configuration examples for Cisco

 


System dimensions

Width: 220mm (without mounting brackets) 430mm (with 19" mounting brachets)

Hight: 44mm

Depth: 105mm

 

Weight

kg

 

PSU specifications

PSU (Power): 2x 1100W (IEC320 C14 connector)

Maximum heat dissipation: 4100BTU/h

Frequency: 50Hz

Voltage: 240V AC

Maximum current: 6.5A

Power based on observation: 500W maximum, 350W average (both PSU powered)