Network connections (appliance rear view)

This picture shows the minimal set of ports that must be connected.

 

PMA-222 Min Conn.png
PMA-222 Min Conn.png

 

Located on the appliance's motherboard:

Ports for management interface and virtual console (iDRAC): 1000BASE-T

Management interface (MGT): 2x 1000BASE-T and 2x 10GBASE-T. At least one of these ports must be connected to the network.  This picture show a connection to the third port from the left.  

Located on the NETSCOUT ASI Accelerator NIC:

Monitor (MON): 4x SFP+. These slots are empty and must be equipped with compatible fiber optic transceivers. Attention: copper transceivers are not supported. At least one of these ports must be connected to a SPAN or TAP output.  Ports are numbered from right to left, starting with names if3, if4, if5 and if6.

 

System dimensions

Width: 430.0mm (19 inch)

Hight: 86.8mm (2U)

Depth: 715.5mm

 

Weight (without rails)

33.1kg

 

Weight (including sliding rails and cable management)

36kg

 

PSU specifications

PSU (Power): 2x 1100W (IEC320 C14 connector)

Maximum heat dissipation: 4100BTU/h

Frequency: 50Hz

Voltage: 240V AC

Maximum current: 6.5A

Measured power consumption: 500W maximum, 350W average (both PSU cabled and active)