PMA-2XX Physical installation connections and environmental specifications

From wiki.comcert.com
Revision as of 09:15, 7 January 2021 by Bert (talk | contribs)
Jump to navigation Jump to search

Network connections (appliance rear view)

This picture shows the minimal set of ports to be connected to operate.

For other configurations, please contact COMCERT support.

 

PMA-222 Min Conn.png
PMA-222 Min Conn.png

 

Located on the appliance's motherboard:

Ports for management interface and virtual console (iDRAC): 1000BASE-T

Management interface (MGT): 2x 1000BASE-T and 2x 10GBASE-T. At least one of these ports must be connected to the network.  This picture show a connection to the third port from the left.  

Located on the NETSCOUT ASI Accelerator NIC:

Monitor (MON): 4x SFP+. These slots are empty and must be equipped with compatible fiber optic transceivers. Attention: copper transceivers are not supported. At least one of these ports must be connected to a SPAN or TAP output.  Ports are numbered from right to left, starting with names if3, if4, if5 and if6.

 

System dimensions

Width: 430.0mm (19 inch)

Hight: 86.8mm (2U)

Depth: 715.5mm

 

Weight (without rails)

Without rails 33.1kg

Including sliding rails and cable management 36.0kg

 

Power and heat

PSU (Power): 2x 1100W (IEC320 C14 connector)

Maximum heat dissipation: 4100BTU/h

Frequency: 50Hz

Voltage: 240V AC

Maximum current: 6.5A