PMA-2XX Physical installation connections and environmental specifications

From wiki.comcert.com
Revision as of 09:36, 7 January 2021 by Bert (talk | contribs)
Jump to navigation Jump to search

Network connections (appliance rear view)

This picture shows a minimal set of ports to be connected in order to operate.

For other configurations, please contact COMCERT support.

 

PMA-222 Min Conn.png
PMA-222 Min Conn.png

 

Located on the appliance's motherboard:

Ports for management interface and virtual console (iDRAC): This is a 1000BASE-T Ethernet interface.

Management interface (MGT) (left to right): 2x 10GBASE-T and 2x 1000BASE-T. At least one of these ports must be connected to the network.  This picture show a connection to the third port from the left.  This is a 1000BASE-T Ethernet interface.

Located on the NETSCOUT ASI Accelerator NIC:

Monitor (MON): 4x SFP+. These slots are empty and must be equipped with compatible fiber optic transceivers. Attention: copper transceivers are not supported. At least one of these ports must be connected to a SPAN or TAP output.  Ports are numbered (right to left) if3, if4, if5 and if6.

 

Dimensions

Width: 430.0mm (19 inch)

Hight: 86.8mm (2U)

Depth: 715.5mm

 

Weight

Without rails 33.1kg

Including sliding rails and cable management 36.0kg

 

Power and heat

PSU (Power): 2x 1100W (ISO/IEC320 C14 connector)

Maximum heat dissipation: 4100BTU/h

Frequency: 50Hz

Voltage: 240V AC

Maximum current: 6.5A

Measured power consumption: 500W maximum, 350W average (both PSU cabled and active)

 

Accessories

  • 2x ISO/IEC320 C13/C14 cables 2m
  • 2x ISO/IEC320 C13/C14 cables 5m
  • 1x pair of sliding rails
  • 1x cable management arm

In accordance with COMCERT's policy for sustainability, unwanted accessories are preferably recuperated for reuse.