PMA-2XX Physical installation connections and environmental specifications
Network connections (appliance rear view)
This picture assumes the PMA isbeing used as a NETSCOUT InfiniStream Appliance. It shows a minimal set of ports to be connected in order to operate fully.
For other configuration options, please contact COMCERT support.
Located on the appliance motherboard:
- Management interfaces (MGT) from left to right: 10GBASE-T, 10GBASE-T, 1000BASE-T and 1000BASE-T. One of these ports must be connected to the network. This picture shows a connection to the third port from the left. This is a 1000BASE-T Ethernet interface. Make sure the port is connected when running the appliance configuration utility.
- Dedicated virtual console interface (iDRAC): This is a 1000BASE-T Ethernet interface.
Located on the NETSCOUT ASI Accelerator NIC:
- Monitor interfaces (MON): 4x SFP+. These slots are empty and are to be equipped with compatible fiber optic transceivers. Attention: copper transceivers are not supported. At least one of these ports must be connected to a SPAN or TAP output. These ports are named (from right to left) if3, if4, if5 and if6.
Dimensions
- Width: 430.0mm (19 inch)
- Hight: 86.8mm (2U)
- Depth: 715.5mm
Weight
- Without rails 33.1kg
- Including sliding rails and cable management 36.0kg
Power and heat
- PSU (Power): 2x 1100W (ISO/IEC320 C14 connector)
- Maximum heat dissipation: 4100BTU/h
- Frequency: 50Hz
- Voltage: 240V AC
- Maximum current: 6.5A
- Measured power consumption: 500W maximum, 350W average (both PSU cabled and active)
Accessories
- 2x ISO/IEC320 C13/C14 cable 2m
- 2x ISO/IEC320 C13/C14 cable 5m
- 1x pair of sliding rails
- 1x cable management arm
In accordance with COMCERT Procedures for the Protection of the Environment and Sustainability, unwanted accessories can be returned to COMCERT for reuse.