PMA-2XX Physical installation connections and environmental specifications

From wiki.comcert.com
Revision as of 15:17, 29 January 2022 by Bert (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Network connections (appliance rear view)

This picture assumes the PMA isbeing used as a NETSCOUT InfiniStream Appliance.  It shows a minimal set of ports to be connected in order to operate fully.

For other configuration options, please contact COMCERT support.

 

PMA-222 Min Conn.png
PMA-222 Min Conn.png

 

Located on the appliance motherboard:

  • Management interfaces (MGT) from left to right: 10GBASE-T, 10GBASE-T, 1000BASE-T and 1000BASE-T.  One of these ports must be connected to the network.  By default, the third port from the left is used as the appliance management interface.
  • Dedicated virtual console interface (iDRAC).  This is a 1000BASE-T Ethernet interface.

Located on the NETSCOUT ASI Accelerator NIC:

  • Monitor interfaces (MON): 4x SFP+ slots. These slots are empty and are to be equipped with compatible fiber optic transceivers.  Attention: copper transceivers are not supported.  At least one of these ports must be connected to a SPAN or TAP output.  These ports are named (from right to left) if3, if4, if5 and if6.

 

Dimensions

  • Width: 430.0mm (19 inch)
  • Hight: 86.8mm (2U)
  • Depth: 715.5mm

 

Weight

  • Without rails 29kg
  • Including sliding rails and cable management 32kg

 

Power and heat

  • PSU (Power): 2x 1100W (ISO/IEC320 C14 connector)
  • Maximum heat dissipation: 4100BTU/h
  • Frequency: 50Hz
  • Voltage: 240V AC
  • Maximum current: 6.5A
  • Measured power consumption: 500W maximum, 350W average (both PSU cabled and active)

 

Accessories

  • 2x ISO/IEC320 C13/C14 cable
  • 1x pair of sliding rails
  • 1x cable management arm

In accordance with COMCERT Durability Procedures, unwanted accessories may be returned to COMCERT for re-use.