NVP for generic cable types: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
(Created page with " == Introduction == A correct configuration of NVP assures the most accurate calculation of the electrical length of the link under test.    == Solution == These...")
 
No edit summary
 
(12 intermediate revisions by the same user not shown)
Line 2: Line 2:
== Introduction ==
== Introduction ==


A correct configuration of NVP assures the most accurate calculation of the electrical length of the link under test. 
Correct configuration of NVP ensures the most accurate determination of cable length during testing. 


 
 
Line 8: Line 8:
== Solution ==
== Solution ==


These are the values for NVP for the most common types of twisted-pair cable. 
These are the average values for NVP (%) for some generic types of twisted-pair cable.  


Use these values whenever the manufacturer of the cable is unknown, or the link is composed of diferent brands of cable.
Standards stipulate that NVP must be specified at 10MHz signal at 20°C (68°F).
 
(Source: [https://www.flukenetworks.com Fluke Networks])
 
{| align="center" border="2" cellpadding="1" cellspacing="1" style="width: 500px;"
|-
! scope="col" | Category
! scope="col" | U/UTP
! scope="col" | U/FTP
! scope="col" | F/UTP
! scope="col" | S/FTP
|-
| 5e
| 69
| -
| 69
| -
|-
| 6
| 69
| 74
| 70
| -
|-
| 6A
| 68.2
| 74
| 74
| 77
|-
| 7
| -
| -
| -
| 78
|-
| 7A
| -
| -
| -
| 78
|-
| 8
| -
| -
| -
|
72
 
|}
 
 

Latest revision as of 15:17, 7 April 2024

Introduction

Correct configuration of NVP ensures the most accurate determination of cable length during testing. 

 

Solution

These are the average values for NVP (%) for some generic types of twisted-pair cable.  

Standards stipulate that NVP must be specified at 10MHz signal at 20°C (68°F).

(Source: Fluke Networks)

Category U/UTP U/FTP F/UTP S/FTP
5e 69 - 69 -
6 69 74 70 -
6A 68.2 74 74 77
7 - - - 78
7A - - - 78
8 - - -

72