Connecting a passive TAP

From wiki.comcert.com
Jump to navigation Jump to search

Introduction

Passive Fiber Optic TAPs require little or no configuration. While cabling the network - and site ports is straight forward, the cabling between the TAP output and the NETSCOUT Accelerator NIC is somewhat special.

 

Solution

 

 

 

 

LC SM/MM HD Fiber TAP

The label on the tap indicated where the light should arrive (Rx) and where it will be transmitted (Tx). 

TAP internal wiring:

 

TAPInternalCabling.png

Y-cable

The two fibers of the duplex LC-LC output of the TAP - indicated with "monitor 1A and 1B" - are used for transmission.

To connect to the NETSCOUT Accelerator NIC, you need a LC-LC-duplex to 2x LC-simplex Y-cable.  It is very simple to make a cable like this from a standard duplex fiber optic patch cord:

 

LCLCFanOut.jpg

 

Connecting the TAP to the NETSCOUT Accelerator NIC

Both LC-simplex connectors of the Y-cable must be connected to the input (Rx) of two  ports on the NETSCOUT Accelerator NIC on the rear of the appliance.  The ports are numberd from top to bottom.  Some appliances (like the PMA-2XX) have the card rotated 90° clockwise.  In that case nubers start from right to left.  If not fully used, connect the lowest port numbers first.

The following picture is showing the TAP - situated on top of the appliance - while the output is connected with a Y-cable to the first and second interface (equiped with 10GBASE-SX SFP+) of the NETSCOUT Accelerator NIC.  The TAP is not yet brought in line.

 

TAPConnectNIC.jpg

 

Port aggregation

An aggregate must be created from the two connected ports. Ask your COMCERT Engineer to configure a Port Aggregate or read the Agent Configuration Utility for CDM/ASI Administration Guide carefully for details on how to create a Port Aggregate.