PMA-XX Environmental specifications: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
 
(26 intermediate revisions by the same user not shown)
Line 1: Line 1:


=== Network connections (appliance rear view) ===
== Introduction ==
 
These specifications are valid for both PMA-65, PMA-85 appliances.
 
 
 
== Solution ==
 
=== Appliance rear view ===


This picture shows the connection on the rear of the appliance.
This picture shows the connection on the rear of the appliance.
Line 10: Line 18:
 
 


==== IP remote management interface (iDRAC): 1x 1000BASE-T ====
 
 
=== Network connections ===


Management ports (MGT1 & MGT2): 2x 1000BASE-T
IP remote management interface (<span style="background-color:#F0FFF0;">iDRAC</span>): 1x 1000BASE-T


These two management ports for a team that form a redundant uplink to the network
Management ports (<span style="background-color:#F0FFFF;">MGT1</span> & <span style="background-color:#F0FFFF;">MGT2</span>): 2x 1000BASE-T


Optional monitor port (MON1 & MON2): 2x 1000BASE-T
*''These&nbsp;ports provide a redundant connection with the network''
*''At least one of these ports must be connected''


These ports&nbsp;&nbsp;
Monitor port (<span style="background-color:#FFFFE0;">MON1</span> & <span style="background-color:#FFFFE0;">MON2</span>): 2x 1000BASE-T
 
*''The purpose of these monitor ports will depend on the software running on de appliance&nbsp;&nbsp;''
*''Example1: on PMA-XX with a packet collector, these ports will be two ingress ports''
*''Example2: on PMA-XX with a flow collector, these ports will be assigned to the flow collector and&nbsp;provide a redundant connection with the network''
*''In both examples, at least one of these ports must be connected''


&nbsp;
&nbsp;


=== System dimensions ===
=== Dimensions ===


Width: 430.0mm (19 inch)
Width: 434mm (19" sliding rails)


Hight: 86.8mm (2U)
Hight: 42.4mm (1U)


Depth: 715.5mm
Depth: 715mm


&nbsp;
&nbsp;
Line 34: Line 50:
=== Weight ===
=== Weight ===


33.1kg
17.6kg (without harddisk)


&nbsp;
&nbsp;


=== PSU specifications ===
=== Power ===


PSU (Power): 2x 1100W (IEC320 C14 connector)
PSU: 2x 550W (IEC320 C14 connector)


Maximum heat dissipation: 4100BTU/h
Frequency: 50/60Hz


Frequency: 50Hz
Voltage: 100-240V AC


Voltage: 240V AC
Maximum current: 3.5A


Maximum current: 6.5A
Raw power consumption: 130W


Power based on observation: 500W maximum, 350W average (both PSU powered)
Measured 7-day maximum power consumption: PMA-65: 114W / PMA-85: 203W


&nbsp;
&nbsp;


=== Network connections ===
=== Heating ===
 
Raw heat dissipation: 444BTU/h
 
Measured 7-day maximum heat dissipation: PMA-65: 389BTU/h&nbsp;/ PMA-85: 693BTU/h
 
&nbsp;


==== Located on the server's motherboard: ====
=== Noise ===


Out-of-band management and virtual console (iDRAC): 1x 1000BASE-T
A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA


Management (MGT): 2x 1000BASE-T and 2x 10GBASE-T. At least one of these ports must be connected to a switch port.
&nbsp;


==== Located on the ASI Accelerator NIC: ====
=== Environment ===


Monitor (MON): 4x SFP+. These slots are empty and must be equipped with fiber optic transceivers. <span style="background-color:#FFFF00">Copper transceivers are not supported</span>. One or more of these ports must be connected to a SPAN or TAP.&nbsp; Ports are numbered from right to left, starting at number 3 then 4, 5 and 6.<br/> &nbsp;
Storage: -40°C to 65°C and 5% to 95% RH


[[Category:Pages with broken file links]]
Operation: 10°C to 35°C and 10% to 80% RH

Latest revision as of 08:00, 3 September 2021

Introduction

These specifications are valid for both PMA-65, PMA-85 appliances.

 

Solution

Appliance rear view

This picture shows the connection on the rear of the appliance.

 

PMAXXREARConnections.png
PMAXXREARConnections.png

 

 

Network connections

IP remote management interface (iDRAC): 1x 1000BASE-T

Management ports (MGT1 & MGT2): 2x 1000BASE-T

  • These ports provide a redundant connection with the network
  • At least one of these ports must be connected

Monitor port (MON1 & MON2): 2x 1000BASE-T

  • The purpose of these monitor ports will depend on the software running on de appliance  
  • Example1: on PMA-XX with a packet collector, these ports will be two ingress ports
  • Example2: on PMA-XX with a flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network
  • In both examples, at least one of these ports must be connected

 

Dimensions

Width: 434mm (19" sliding rails)

Hight: 42.4mm (1U)

Depth: 715mm

 

Weight

17.6kg (without harddisk)

 

Power

PSU: 2x 550W (IEC320 C14 connector)

Frequency: 50/60Hz

Voltage: 100-240V AC

Maximum current: 3.5A

Raw power consumption: 130W

Measured 7-day maximum power consumption: PMA-65: 114W / PMA-85: 203W

 

Heating

Raw heat dissipation: 444BTU/h

Measured 7-day maximum heat dissipation: PMA-65: 389BTU/h / PMA-85: 693BTU/h

 

Noise

A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA

 

Environment

Storage: -40°C to 65°C and 5% to 95% RH

Operation: 10°C to 35°C and 10% to 80% RH