PMA-XX Environmental specifications: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
 
(3 intermediate revisions by the same user not shown)
Line 32: Line 32:


*''The purpose of these monitor ports will depend on the software running on de appliance  ''  
*''The purpose of these monitor ports will depend on the software running on de appliance  ''  
*''On PMA-XX with packet collector, these ports will be two independent packet ingress ports''  
*''Example1: on PMA-XX with a packet collector, these ports will be two ingress ports''  
*''On PMA-XX with flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network''  
*''Example2: on PMA-XX with a flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network''  
*''At least one of these ports must be connected''  
*''In both examples, at least one of these ports must be connected''  


 
 
Line 50: Line 50:
=== Weight ===
=== Weight ===


17.6kg (without disk)
17.6kg (without harddisk)


 
 
Line 64: Line 64:
Maximum current: 3.5A
Maximum current: 3.5A


Measured 7-day average power: PMA-65: 90W / PMA-85: 203W
Raw power consumption: 130W
 
Measured 7-day maximum power consumption: PMA-65: 114W / PMA-85: 203W


 
 
Line 70: Line 72:
=== Heating ===
=== Heating ===


Maximum heat dissipation: 2559BTU/h
Raw heat dissipation: 444BTU/h
 
Measured 7-day maximum heat dissipation: PMA-65: 389BTU/h / PMA-85: 693BTU/h


 
 

Latest revision as of 08:00, 3 September 2021

Introduction

These specifications are valid for both PMA-65, PMA-85 appliances.

 

Solution

Appliance rear view

This picture shows the connection on the rear of the appliance.

 

PMAXXREARConnections.png
PMAXXREARConnections.png

 

 

Network connections

IP remote management interface (iDRAC): 1x 1000BASE-T

Management ports (MGT1 & MGT2): 2x 1000BASE-T

  • These ports provide a redundant connection with the network
  • At least one of these ports must be connected

Monitor port (MON1 & MON2): 2x 1000BASE-T

  • The purpose of these monitor ports will depend on the software running on de appliance  
  • Example1: on PMA-XX with a packet collector, these ports will be two ingress ports
  • Example2: on PMA-XX with a flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network
  • In both examples, at least one of these ports must be connected

 

Dimensions

Width: 434mm (19" sliding rails)

Hight: 42.4mm (1U)

Depth: 715mm

 

Weight

17.6kg (without harddisk)

 

Power

PSU: 2x 550W (IEC320 C14 connector)

Frequency: 50/60Hz

Voltage: 100-240V AC

Maximum current: 3.5A

Raw power consumption: 130W

Measured 7-day maximum power consumption: PMA-65: 114W / PMA-85: 203W

 

Heating

Raw heat dissipation: 444BTU/h

Measured 7-day maximum heat dissipation: PMA-65: 389BTU/h / PMA-85: 693BTU/h

 

Noise

A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA

 

Environment

Storage: -40°C to 65°C and 5% to 95% RH

Operation: 10°C to 35°C and 10% to 80% RH